Skip to main content

Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients.

Publication ,  Journal Article
Zhang, L; Yin, F-F; Li, T; Teng, X; Xiao, H; Harris, W; Ren, L; Kong, F-MS; Ge, H; Mao, R; Cai, J
Published in: Med Phys
December 2021

PURPOSE: To develop a novel multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI) technique that expands single image contrast 4D-MRI to a spectrum of native and synthetic image contrasts and to evaluate its feasibility in liver tumor patients. METHODS AND MATERIALS: The MC-4D-MRI technique integrates multi-parametric MRI fusion, 4D-MRI, and deformable image registration (DIR) techniques. The fusion technique consists of native MRI as input, image pre-processing, fusion algorithm, adaptation, and fused multi-contrast MRI as output. Four-dimensional deformation vector fields (4D-DVF) were generated from an original T2/T1-w 4D-MRI by deforming end-of-inhalation (EOI) to nine other phase volumes via DIR. The 4D-DVF were applied to multi-contrast MRI to generate a spectrum of 4D-MRI in different image contrasts. The MC-4D-MRI technique was evaluated in five liver tumor patients on tumor contrast-to-noise ratio (CNR), internal target volume (ITV) contouring consistency, diaphragm motion range, and tumor motion trajectory; and in digital anthropomorphic phantoms on 4D-DIR introduced errors in tumor motion range, centroid location, extent, and volume. RESULTS: MC-4D-MRI consisting of 4D-MRIs in native image contrasts (T1-w, T2-w, and T2/T1-w) and synthetic image contrasts, such as tumor-enhanced contrast (TEC) were generated in five liver tumor patients. Patient tumor CNR increased from 2.6 ± 1.8 in the T2/T1-w MRI, to -4.4 ± 2.4, 6.6 ± 3.0, and 9.6 ± 3.9 in the T1-w, T2-w, and TEC MRI, respectively. Patient ITV inter-observer mean Dice similarity coefficient (mDSC) increased from 0.65 ± 0.10 in the original T2/T1-w 4D-MRI, to 0.76 ± 0.14, 0.77 ± 0.12, and 0.86 ± 0.05 in the T1-w, T2-w, and TEC 4D-MRI, respectively. Patient diaphragm motion range absolute differences between the three new 4D-MRIs and original T2/T1-w 4D-MRI were 1.2 ± 1.3, 0.3 ± 0.7, and 0.5 ± 0.5 mm, respectively. Patient tumor displacement phase-averaged absolute differences between the three 4D-MRIs and the original 4D-MRI were 0.72 ± 0.33, 0.62 ± 0.54, and 0.74 ± 0.43 mm in the superior-inferior (SI) direction, and 0.59 ± 0.36, 0.51 ± 0.30, and 0.50 ± 0.24 mm in the anterior-posterior (AP) direction, respectively. In the digital phantoms, phase-averaged absolute tumor centroid shift caused by the 4D-DIR were at or below 0.5 mm in SI, AP, and left-right (LR) directions. CONCLUSION: We developed an MC-4D-MRI technique capable of expanding single image contrast 4D-MRI along a new dimension of image contrast. Initial evaluations in liver tumor patients showed enhancements in image contrast variety, tumor contrast, and ITV contouring consistencies using MC-4D-MRI. The technique might offer new perspectives on the image contrast of MRI and 4D-MRI in MR-guided radiotherapy.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

December 2021

Volume

48

Issue

12

Start / End Page

7984 / 7997

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Magnetic Resonance Imaging
  • Liver Neoplasms
  • Image Processing, Computer-Assisted
  • Humans
  • Four-Dimensional Computed Tomography
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, L., Yin, F.-F., Li, T., Teng, X., Xiao, H., Harris, W., … Cai, J. (2021). Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients. Med Phys, 48(12), 7984–7997. https://doi.org/10.1002/mp.15314
Zhang, Lei, Fang-Fang Yin, Tian Li, Xinzhi Teng, Haonan Xiao, Wendy Harris, Lei Ren, et al. “Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients.Med Phys 48, no. 12 (December 2021): 7984–97. https://doi.org/10.1002/mp.15314.
Zhang L, Yin F-F, Li T, Teng X, Xiao H, Harris W, et al. Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients. Med Phys. 2021 Dec;48(12):7984–97.
Zhang, Lei, et al. “Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients.Med Phys, vol. 48, no. 12, Dec. 2021, pp. 7984–97. Pubmed, doi:10.1002/mp.15314.
Zhang L, Yin F-F, Li T, Teng X, Xiao H, Harris W, Ren L, Kong F-MS, Ge H, Mao R, Cai J. Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients. Med Phys. 2021 Dec;48(12):7984–7997.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

December 2021

Volume

48

Issue

12

Start / End Page

7984 / 7997

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Magnetic Resonance Imaging
  • Liver Neoplasms
  • Image Processing, Computer-Assisted
  • Humans
  • Four-Dimensional Computed Tomography
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering