Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study.

Publication ,  Journal Article
Yang, Z; Ren, L; Yin, F-F; Liang, X; Cai, J
Published in: Radiat Med Prot
March 2020

PURPOSE: Motion artifacts induced by breathing variations are common in 4D-MRI images. This study aims to reduce the motion artifacts by developing a novel, robust 4D-MRI sorting method based on anatomic feature matching and applicable in both cine and sequential acquisition. METHOD: The proposed method uses the diaphragm as the anatomic feature to guide the sorting of 4D-MRI images. Initially, both abdominal 2D sagittal cine MRI images and axial MRI images were acquired. The sagittal cine MRI images were divided into 10 phases as ground truth. Next, the phase of each axial MRI image is determined by matching its diaphragm position in the intersection plane to the ground truth cine MRI. Then, those matched phases axial images were sorted into 10-phase bins which were identical to the ground truth cine images. Finally, 10-phase 4D-MRI were reconstructed from these sorted axial images. The accuracy of reconstructed 4D-MRI data was evaluated by comparing with the ground truth using the 4D extended Cardiac Torso (XCAT) digital phantom. The effects of breathing signal, including both regular (cosine function) and irregular (patient data) in both axial cine and sequential scanning modes, on reconstruction accuracy were investigated by calculating total relative error (TRE) of the 4D volumes, Volume-Percent-Difference (VPD) and Center-of-Mass-Shift (COMS) of the estimated tumor volume, compared with the ground truth XCAT images. RESULTS: In both scanning modes, reconstructed 4D-MRI images matched well with ground truth with minimal motion artifacts. The averaged TRE of the 4D volume, VPD and COMS of the EOE phase in both scanning modes are 0.32%/1.20%/±0.05 mm for regular breathing, and 1.13%/4.26%/±0.21 mm for patient irregular breathing. CONCLUSION: The preliminary evaluation results illustrated the feasibility of the robust 4D-MRI sorting method based on anatomic feature matching. This method provides improved image quality with reduced motion artifacts for both cine and sequential scanning modes.

Duke Scholars

Published In

Radiat Med Prot

DOI

EISSN

2666-5557

Publication Date

March 2020

Volume

1

Issue

1

Start / End Page

41 / 47

Location

Netherlands
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yang, Z., Ren, L., Yin, F.-F., Liang, X., & Cai, J. (2020). Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study. Radiat Med Prot, 1(1), 41–47. https://doi.org/10.1016/j.radmp.2020.01.003
Yang, Zi, Lei Ren, Fang-Fang Yin, Xiao Liang, and Jing Cai. “Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study.Radiat Med Prot 1, no. 1 (March 2020): 41–47. https://doi.org/10.1016/j.radmp.2020.01.003.
Yang Z, Ren L, Yin F-F, Liang X, Cai J. Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study. Radiat Med Prot. 2020 Mar;1(1):41–7.
Yang, Zi, et al. “Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study.Radiat Med Prot, vol. 1, no. 1, Mar. 2020, pp. 41–47. Pubmed, doi:10.1016/j.radmp.2020.01.003.
Yang Z, Ren L, Yin F-F, Liang X, Cai J. Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study. Radiat Med Prot. 2020 Mar;1(1):41–47.

Published In

Radiat Med Prot

DOI

EISSN

2666-5557

Publication Date

March 2020

Volume

1

Issue

1

Start / End Page

41 / 47

Location

Netherlands