Skip to main content

A dual-supervised deformation estimation model (DDEM) for constructing ultra-quality 4D-MRI based on a commercial low-quality 4D-MRI for liver cancer radiation therapy.

Publication ,  Journal Article
Xiao, H; Ni, R; Zhi, S; Li, W; Liu, C; Ren, G; Teng, X; Liu, W; Wang, W; Zhang, Y; Wu, H; Lee, H-FV; Cheung, L-YA; Chang, H-CC; Li, T; Cai, J
Published in: Med Phys
May 2022

BACKGROUND: Most available four-dimensional (4D)-magnetic resonance imaging (MRI) techniques are limited by insufficient image quality and long acquisition times or require specially designed sequences or hardware that are not available in the clinic. These limitations have greatly hindered the clinical implementation of 4D-MRI. PURPOSE: This study aims to develop a fast ultra-quality (UQ) 4D-MRI reconstruction method using a commercially available 4D-MRI sequence and dual-supervised deformation estimation model (DDEM). METHODS: Thirty-nine patients receiving radiotherapy for liver tumors were included. Each patient was scanned using a time-resolved imaging with interleaved stochastic trajectories (TWIST)-lumetric interpolated breath-hold examination (VIBE) MRI sequence to acquire 4D-magnetic resonance (MR) images. They also received 3D T1-/T2-weighted MRI scans as prior images, and UQ 4D-MRI at any instant was considered a deformation of them. A DDEM was developed to obtain a 4D deformable vector field (DVF) from 4D-MRI data, and the prior images were deformed using this 4D-DVF to generate UQ 4D-MR images. The registration accuracies of the DDEM, VoxelMorph (normalized cross-correlation [NCC] supervised), VoxelMorph (end-to-end point error [EPE] supervised), and the parametric total variation (pTV) algorithm were compared. Tumor motion on UQ 4D-MRI was evaluated quantitatively using region of interest (ROI) tracking errors, while image quality was evaluated using the contrast-to-noise ratio (CNR), lung-liver edge sharpness, and perceptual blur metric (PBM). RESULTS: The registration accuracy of the DDEM was significantly better than those of VoxelMorph (NCC supervised), VoxelMorph (EPE supervised), and the pTV algorithm (all, p < 0.001), with an inference time of 69.3 ± 5.9 ms. UQ 4D-MRI yielded ROI tracking errors of 0.79 ± 0.65, 0.50 ± 0.55, and 0.51 ± 0.58 mm in the superior-inferior, anterior-posterior, and mid-lateral directions, respectively. From the original 4D-MRI to UQ 4D-MRI, the CNR increased from 7.25 ± 4.89 to 18.86 ± 15.81; the lung-liver edge full-width-at-half-maximum decreased from 8.22 ± 3.17 to 3.65 ± 1.66 mm in the in-plane direction and from 8.79 ± 2.78 to 5.04 ± 1.67 mm in the cross-plane direction, and the PBM decreased from 0.68 ± 0.07 to 0.38 ± 0.01. CONCLUSION: This novel DDEM method successfully generated UQ 4D-MR images based on a commercial 4D-MRI sequence. It shows great promise for improving liver tumor motion management during radiation therapy.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

May 2022

Volume

49

Issue

5

Start / End Page

3159 / 3170

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Motion
  • Magnetic Resonance Imaging
  • Liver Neoplasms
  • Image Processing, Computer-Assisted
  • Humans
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Xiao, H., Ni, R., Zhi, S., Li, W., Liu, C., Ren, G., … Cai, J. (2022). A dual-supervised deformation estimation model (DDEM) for constructing ultra-quality 4D-MRI based on a commercial low-quality 4D-MRI for liver cancer radiation therapy. Med Phys, 49(5), 3159–3170. https://doi.org/10.1002/mp.15542
Xiao, Haonan, Ruiyan Ni, Shaohua Zhi, Wen Li, Chenyang Liu, Ge Ren, Xinzhi Teng, et al. “A dual-supervised deformation estimation model (DDEM) for constructing ultra-quality 4D-MRI based on a commercial low-quality 4D-MRI for liver cancer radiation therapy.Med Phys 49, no. 5 (May 2022): 3159–70. https://doi.org/10.1002/mp.15542.
Xiao H, Ni R, Zhi S, Li W, Liu C, Ren G, Teng X, Liu W, Wang W, Zhang Y, Wu H, Lee H-FV, Cheung L-YA, Chang H-CC, Li T, Cai J. A dual-supervised deformation estimation model (DDEM) for constructing ultra-quality 4D-MRI based on a commercial low-quality 4D-MRI for liver cancer radiation therapy. Med Phys. 2022 May;49(5):3159–3170.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

May 2022

Volume

49

Issue

5

Start / End Page

3159 / 3170

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Motion
  • Magnetic Resonance Imaging
  • Liver Neoplasms
  • Image Processing, Computer-Assisted
  • Humans
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering