Skip to main content
Journal cover image

Cerebral blood volume measured with inhaled C15O and positron emission tomography.

Publication ,  Journal Article
Martin, WR; Powers, WJ; Raichle, ME
Published in: J Cereb Blood Flow Metab
August 1987

Local cerebral blood volume (CBV) has been measured previously with inhaled 11CO and positron emission tomography (PET). The model used assumes that equilibrium in tracer concentration has occurred between arterial and systemic venous blood before the PET measurement is made. To verify that this model may be used with the much shorter half-lived C15O, we have simultaneously measured arterial and venous blood radioactivity following C15O inhalation. Equilibrium occurred 95 +/- 39 s after inhalation (n = 7). If the PET measurement is commenced prior to arteriovenous equilibrium, significant errors occur in calculated CBV. These data indicate that C15O may be used as a tracer for CBV measurement provided that emission data collection commences at approximately 120 s after inhalation. Strict quality control measures must be maintained to minimize the contamination of administered C15O with 15O-labeled CO2.

Duke Scholars

Published In

J Cereb Blood Flow Metab

DOI

ISSN

0271-678X

Publication Date

August 1987

Volume

7

Issue

4

Start / End Page

421 / 426

Location

United States

Related Subject Headings

  • Tomography, Emission-Computed
  • Postural Balance
  • Oxygen Radioisotopes
  • Neurology & Neurosurgery
  • Humans
  • Cerebrovascular Circulation
  • Carbon Monoxide
  • Brain
  • Blood Volume
  • Administration, Inhalation
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Martin, W. R., Powers, W. J., & Raichle, M. E. (1987). Cerebral blood volume measured with inhaled C15O and positron emission tomography. J Cereb Blood Flow Metab, 7(4), 421–426. https://doi.org/10.1038/jcbfm.1987.85
Martin, W. R., W. J. Powers, and M. E. Raichle. “Cerebral blood volume measured with inhaled C15O and positron emission tomography.J Cereb Blood Flow Metab 7, no. 4 (August 1987): 421–26. https://doi.org/10.1038/jcbfm.1987.85.
Martin WR, Powers WJ, Raichle ME. Cerebral blood volume measured with inhaled C15O and positron emission tomography. J Cereb Blood Flow Metab. 1987 Aug;7(4):421–6.
Martin, W. R., et al. “Cerebral blood volume measured with inhaled C15O and positron emission tomography.J Cereb Blood Flow Metab, vol. 7, no. 4, Aug. 1987, pp. 421–26. Pubmed, doi:10.1038/jcbfm.1987.85.
Martin WR, Powers WJ, Raichle ME. Cerebral blood volume measured with inhaled C15O and positron emission tomography. J Cereb Blood Flow Metab. 1987 Aug;7(4):421–426.
Journal cover image

Published In

J Cereb Blood Flow Metab

DOI

ISSN

0271-678X

Publication Date

August 1987

Volume

7

Issue

4

Start / End Page

421 / 426

Location

United States

Related Subject Headings

  • Tomography, Emission-Computed
  • Postural Balance
  • Oxygen Radioisotopes
  • Neurology & Neurosurgery
  • Humans
  • Cerebrovascular Circulation
  • Carbon Monoxide
  • Brain
  • Blood Volume
  • Administration, Inhalation