24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects.

Publication ,  Journal Article
Costa, VP; Zangalli, CS; Jammal, AA; Medeiros, FA; Miyazaki, JVMK; Perez, V; Nardi Boscaroli, ML; Schimiti, RB
Published in: Ophthalmol Glaucoma
2023

PURPOSE: To compare the Swedish Interactive Thresholding Algorithm (SITA) Standard (SS) and SITA Faster (SFR) strategies in normal individuals undergoing standard automated perimetry (SAP) for the first time. DESIGN: Randomized, comparative, observational case series. PARTICIPANTS: Seventy-four perimetry-naive healthy individuals. METHODS: All individuals underwent SAP 24-2 testing with the Humphrey Field Analyzer III (model 850 Zeiss) using the SS and SFR strategies. One eye of each individual was tested. Test order between strategies was randomized, and an interval of 15 minutes was allowed between the tests. MAIN OUTCOME MEASURES: The following variables were compared: test time, foveal threshold, false-positive errors, number of unreliable tests, mean deviation (MD), visual field index (VFI), pattern standard deviation (PSD), glaucoma hemifield test (GHT), and number of depressed points deviating at P < 5%, P < 2%, P < 1%, and P < 0.5% on the total and pattern deviation probability maps. Specificity of the SS and SFR strategies were compared using Anderson's criteria for abnormal visual fields. RESULTS: The SFR tests were 60.4% shorter in time compared with SS (P < 0.001) and were associated with a significantly lower PSD (1.75 ± 0.80 decibel [dB] vs. 2.15 ± 1.25 dB; P = 0.016). There were no significant differences regarding the MD, VFI, foveal threshold, GHT, and number of points depressed at P < 5%, P < 2%, P < 1%, and P < 0.5% on the total deviation and pattern deviation probability maps between SS and SFR. When all exams were analyzed and any of Anderson's criteria was applied, the specificity was 68% with SFR and 61% with SS (P = 0.250). The specificities observed with SFR and SS when only the first or second exams were analyzed were also similar (63% vs. 64% and 72% vs. 58%, respectively, P > 0.05). CONCLUSIONS: The SS and SFR were associated with similar specificities in perimetry-naive individuals. The SFR did not increase the number of depressed points in the total and pattern deviation probability maps. Ophthalmologists should be aware that both strategies are associated with disturbingly high false-positive rates in perimetry-naive individuals. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

Duke Scholars

Published In

Ophthalmol Glaucoma

DOI

EISSN

2589-4196

Publication Date

2023

Volume

6

Issue

2

Start / End Page

129 / 136

Location

United States

Related Subject Headings

  • Visual Fields
  • Visual Field Tests
  • Vision Disorders
  • Sweden
  • Humans
  • Algorithms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Costa, V. P., Zangalli, C. S., Jammal, A. A., Medeiros, F. A., Miyazaki, J. V. M. K., Perez, V., … Schimiti, R. B. (2023). 24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects. Ophthalmol Glaucoma, 6(2), 129–136. https://doi.org/10.1016/j.ogla.2022.08.006
Costa, Vital P., Camila S. Zangalli, Alessandro A. Jammal, Felipe A. Medeiros, João V. M. K. Miyazaki, Vanessa Perez, Maria Letícia Nardi Boscaroli, and Rui B. Schimiti. “24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects.Ophthalmol Glaucoma 6, no. 2 (2023): 129–36. https://doi.org/10.1016/j.ogla.2022.08.006.
Costa VP, Zangalli CS, Jammal AA, Medeiros FA, Miyazaki JVMK, Perez V, et al. 24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects. Ophthalmol Glaucoma. 2023;6(2):129–36.
Costa, Vital P., et al. “24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects.Ophthalmol Glaucoma, vol. 6, no. 2, 2023, pp. 129–36. Pubmed, doi:10.1016/j.ogla.2022.08.006.
Costa VP, Zangalli CS, Jammal AA, Medeiros FA, Miyazaki JVMK, Perez V, Nardi Boscaroli ML, Schimiti RB. 24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects. Ophthalmol Glaucoma. 2023;6(2):129–136.
Journal cover image

Published In

Ophthalmol Glaucoma

DOI

EISSN

2589-4196

Publication Date

2023

Volume

6

Issue

2

Start / End Page

129 / 136

Location

United States

Related Subject Headings

  • Visual Fields
  • Visual Field Tests
  • Vision Disorders
  • Sweden
  • Humans
  • Algorithms