Skip to main content

Ion energy measurements near a dormant cathode in a multiple-cathode gridded ion thruster

Publication ,  Journal Article
Rovey, JL; Gallimore, AD
Published in: Physics of Plasmas
April 8, 2007

A rectangular ion thruster discharge chamber was investigated for operation with multiple discharge cathode assemblies (DCAs). The multiple cathode approach attempts to increase thruster throughput and lifetime by operating three DCAs sequentially, possibly providing a threefold increase in discharge life. Previous multiple-cathode electric propulsion devices, such as the SPT-100, have shown dormant cathode erosion to be a life-limiting phenomenon. Similar results in a multiple-cathode discharge chamber may decrease the anticipated gain in discharge lifetime. In order to assess possible dormant cathode sputtering erosion, a diagnostic canister (DC) was designed and utilized to measure bombarding ion energy at the dormant cathode locations. The DC appeared similar to the active DCA, but was outfitted with a retarding potential analyzer. Most probable ion energy measurements show ions with energy of 27-35 eV (±10%) with respect to cathode common and ion energy increases with increasing magnetic field strength. These results are consistent with an ion falling from the plasma potential to cathode common. A simple sputtering erosion model shows that, if doubly charged ions are present, these energies are enough to cause sputtering erosion of the dormant units. © 2007 American Institute of Physics.

Duke Scholars

Published In

Physics of Plasmas

DOI

ISSN

1070-664X

Publication Date

April 8, 2007

Volume

14

Issue

3

Related Subject Headings

  • Fluids & Plasmas
  • 5109 Space sciences
  • 5106 Nuclear and plasma physics
  • 0203 Classical Physics
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rovey, J. L., & Gallimore, A. D. (2007). Ion energy measurements near a dormant cathode in a multiple-cathode gridded ion thruster. Physics of Plasmas, 14(3). https://doi.org/10.1063/1.2536514
Rovey, J. L., and A. D. Gallimore. “Ion energy measurements near a dormant cathode in a multiple-cathode gridded ion thruster.” Physics of Plasmas 14, no. 3 (April 8, 2007). https://doi.org/10.1063/1.2536514.
Rovey JL, Gallimore AD. Ion energy measurements near a dormant cathode in a multiple-cathode gridded ion thruster. Physics of Plasmas. 2007 Apr 8;14(3).
Rovey, J. L., and A. D. Gallimore. “Ion energy measurements near a dormant cathode in a multiple-cathode gridded ion thruster.” Physics of Plasmas, vol. 14, no. 3, Apr. 2007. Scopus, doi:10.1063/1.2536514.
Rovey JL, Gallimore AD. Ion energy measurements near a dormant cathode in a multiple-cathode gridded ion thruster. Physics of Plasmas. 2007 Apr 8;14(3).

Published In

Physics of Plasmas

DOI

ISSN

1070-664X

Publication Date

April 8, 2007

Volume

14

Issue

3

Related Subject Headings

  • Fluids & Plasmas
  • 5109 Space sciences
  • 5106 Nuclear and plasma physics
  • 0203 Classical Physics
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences