Skip to main content
Journal cover image

A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques.

Publication ,  Journal Article
Lee, YC; Nik Akhtar, M; Kim, Y; Jung, JW
Published in: Brachytherapy
2024

PURPOSE: To provide a practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo (MC) calculation in ocular brachytherapy using 125I Collaborative Ocular Melanoma Study (COMS) plaques. METHODS AND MATERIALS: Using egs_brachy, MC simulations (1) under task group-43 assumptions with fully loaded seed configurations in water (HOMO) and (2) with effects of plaque backing, insert and inter-seed interactions (HETERO) were performed for seven 125I COMS plaques (10 mm-22 mm in diameter), and homogeneous dose (DHOMO) and heterogeneous dose (DHETERO) for central-axis and off-axis points were determined. For DHOMO, 85 Gy was normalized to a depth of 5 mm. Central-axis heterogeneity correction factors (HCFs) from a depth of 0 mm (inner sclera) to 22 mm (opposite retina) were derived from a ratio of DHETERO to DHOMO. Off-axis HCFs for optic disc/macula and lens as a function of distance from optic disc/macula (DT/MT) for various basal dimensions of tumor (BD/BM) were derived from DHETERO/DHOMO. RESULTS: Central-axis HCF varied with a dose reduction of 10.3-19.8% by heterogeneity. Off-axis HCF for optic disc/macula varied significantly depending on DT/MT and BD/BM with a dose reduction of 11.3-38.3%. Off-axis HCF for lens had a dependence on MT and BM with its variation of 11.0-19.0%. A clinical example of using HCFs to estimate DHETERO was presented. CONCLUSIONS: The practical method of using depth-dependent central-axis HCF and DT/MT- and BD/BM-dependent off-axis HCF provided in this study will facilitate a heterogeneous dose estimate for 125I COMS plaques without MC calculations.

Duke Scholars

Published In

Brachytherapy

DOI

EISSN

1873-1449

Publication Date

2024

Volume

23

Issue

3

Start / End Page

377 / 386

Location

United States

Related Subject Headings

  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Oncology & Carcinogenesis
  • Monte Carlo Method
  • Melanoma
  • Iodine Radioisotopes
  • Humans
  • Eye Neoplasms
  • Brachytherapy
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lee, Y. C., Nik Akhtar, M., Kim, Y., & Jung, J. W. (2024). A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques. Brachytherapy, 23(3), 377–386. https://doi.org/10.1016/j.brachy.2024.01.001
Lee, Yongsook C., Mehran Nik Akhtar, Yongbok Kim, and Jae Won Jung. “A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques.Brachytherapy 23, no. 3 (2024): 377–86. https://doi.org/10.1016/j.brachy.2024.01.001.
Lee, Yongsook C., et al. “A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques.Brachytherapy, vol. 23, no. 3, 2024, pp. 377–86. Pubmed, doi:10.1016/j.brachy.2024.01.001.
Journal cover image

Published In

Brachytherapy

DOI

EISSN

1873-1449

Publication Date

2024

Volume

23

Issue

3

Start / End Page

377 / 386

Location

United States

Related Subject Headings

  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Oncology & Carcinogenesis
  • Monte Carlo Method
  • Melanoma
  • Iodine Radioisotopes
  • Humans
  • Eye Neoplasms
  • Brachytherapy
  • 3202 Clinical sciences