Skip to main content

Determination of Energy Resolution for YSO:Ce Detector Modelled with FLUKA Code

Publication ,  Conference
Nadeera Hemamali, GM; Smith, DR; Hobson, PR
Published in: 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference
January 1, 2022

In this paper, a 5×5×5 mm3 YSO:Ce scintillator detector was modelled with FLUKA code, and calculations for the determination of energy resolution are reported using energies of 59.5, 81, 356, and 661.7 keV. We measured the energy resolution of the scintillator detector in the photon energy range of 59.5 to 661.7 keV using radioactive Am-241, Ba-133, and Cs-137 sources and compared the results with the computed energy resolution obtained using FLUKA, the comparison between simulated and measured resolution showing good agreement. This study shows that the FLUKA code can be used to determine the expected energy resolution successfully, saving both financial cost and time in the development of new scintillators and radiation sensors.

Duke Scholars

Published In

2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference

DOI

Publication Date

January 1, 2022
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Nadeera Hemamali, G. M., Smith, D. R., & Hobson, P. R. (2022). Determination of Energy Resolution for YSO:Ce Detector Modelled with FLUKA Code. In 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference. https://doi.org/10.1109/NSS/MIC44845.2022.10398959
Nadeera Hemamali, G. M., D. R. Smith, and P. R. Hobson. “Determination of Energy Resolution for YSO:Ce Detector Modelled with FLUKA Code.” In 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference, 2022. https://doi.org/10.1109/NSS/MIC44845.2022.10398959.
Nadeera Hemamali GM, Smith DR, Hobson PR. Determination of Energy Resolution for YSO:Ce Detector Modelled with FLUKA Code. In: 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference. 2022.
Nadeera Hemamali, G. M., et al. “Determination of Energy Resolution for YSO:Ce Detector Modelled with FLUKA Code.” 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference, 2022. Scopus, doi:10.1109/NSS/MIC44845.2022.10398959.
Nadeera Hemamali GM, Smith DR, Hobson PR. Determination of Energy Resolution for YSO:Ce Detector Modelled with FLUKA Code. 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference. 2022.

Published In

2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference

DOI

Publication Date

January 1, 2022