Improved solution-based SERS detection of creatinine by inducing hydrogen-bonding interaction for effective analyte capture.

Publication ,  Journal Article
Atta, S; Vo-Dinh, T
Published in: Talanta
October 2024

Recently, solution-based surface-enhanced Raman scattering (SERS) detection technique has been widely recognized due to its cost-effectiveness, simplicity, and ease of use. However, solution-based SERS is limited for practical applications mainly because of the weak adsorption affinity of the target biomolecules to the surface of plasmonic nanoparticles. Herein, we developed a highly sensitive solution-based SERS sensing platform based on mercaptopropionic acid (MPA)-capped silver-coated gold nanostars (SGNS@MPA), which allows efficient enrichment on the nanostars surface for improved detection of an analyte: creatinine, a potential biomarker of chronic kidney disease (CKD). The SGNS@MPA exhibited high enrichment ability towards creatinine molecules in alkaline medium (pH-9) through multiple hydrogen bonding interaction, which causes aggregation of the nanoparticles and enhances the SERS signal of creatinine. The detection limit for creatinine was achieved at 0.1 nM, with a limit of detection (LOD) value of 14.6 pM. As a proof-of-concept demonstration, we conducted the first quantitative detection of creatinine in noninvasive human fluids, such as saliva and sweat, under separation-free conditions. We achieved a detection limit of up to 1 nM for both saliva and sweat, with LOD values as low as 0.136 nM for saliva and 0.266 nM for sweat. Overall, our molecular enrichment strategy offers a new way to improve the solution-based SERS detection technique for real-world practical applications in point-of-care settings and low-resource settings.

Duke Scholars

Published In

Talanta

DOI

EISSN

1873-3573

ISSN

0039-9140

Publication Date

October 2024

Volume

278

Start / End Page

126373

Related Subject Headings

  • Spectrum Analysis, Raman
  • Solutions
  • Silver
  • Saliva
  • Metal Nanoparticles
  • Limit of Detection
  • Hydrogen Bonding
  • Humans
  • Gold
  • Creatinine
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Atta, S., & Vo-Dinh, T. (2024). Improved solution-based SERS detection of creatinine by inducing hydrogen-bonding interaction for effective analyte capture. Talanta, 278, 126373. https://doi.org/10.1016/j.talanta.2024.126373
Atta, Supriya, and Tuan Vo-Dinh. “Improved solution-based SERS detection of creatinine by inducing hydrogen-bonding interaction for effective analyte capture.Talanta 278 (October 2024): 126373. https://doi.org/10.1016/j.talanta.2024.126373.
Atta, Supriya, and Tuan Vo-Dinh. “Improved solution-based SERS detection of creatinine by inducing hydrogen-bonding interaction for effective analyte capture.Talanta, vol. 278, Oct. 2024, p. 126373. Epmc, doi:10.1016/j.talanta.2024.126373.
Journal cover image

Published In

Talanta

DOI

EISSN

1873-3573

ISSN

0039-9140

Publication Date

October 2024

Volume

278

Start / End Page

126373

Related Subject Headings

  • Spectrum Analysis, Raman
  • Solutions
  • Silver
  • Saliva
  • Metal Nanoparticles
  • Limit of Detection
  • Hydrogen Bonding
  • Humans
  • Gold
  • Creatinine