Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.

Publication ,  Journal Article
Quigley, PJ; Hinohara, T; Phillips, HR; Peter, RH; Behar, VS; Kong, Y; Simonton, CA; Perez, JA; Stack, RS
Published in: Circulation
November 1988

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between two inflations by standard angioplasty catheters. Chest pain score, 12-lead electrocardiogram, heart rate, and mean aortic pressure were recorded before each inflation and at 1-minute intervals after inflation. Inflation duration during autoperfusion angioplasty (513 +/- 303 seconds) was longer than for the pre- (107 +/- 55 seconds, p = 0.0004) and post- (139 +/- 71 seconds, p = 0.0006) standard dilatations. The maximum ST-segment elevation and depression in any lead during autoperfusion angioplasty (0.3 +/- 0.5 and 0.6 +/- 0.8 mm) was significantly less than for the pre- (2.4 +/- 1.7 mm, p = 0.002 and 2.2 +/- 1.3 mm, p = 0.0004) or post- (1.9 +/- 1.3 mm, p = 0.002 and 1.6 +/- 1.3 mm, p = 0.018) standard dilatations at the same point in time. Maximal chest pain score during autoperfusion (3.2 +/- 3.5) was lower than for the pre- (6.1 +/- 2.1, p = 0.003) but not the post- (5.2 +/- 3.1, p = 0.07) standard angioplasty. All 11 patients underwent successful, uncomplicated procedures. We conclude that this autoperfusion catheter significantly reduces ischemic symptoms and signs during coronary angioplasty, allowing prolonged periods of balloon inflation.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

ISSN

0009-7322

Publication Date

November 1988

Volume

78

Issue

5 Pt 1

Start / End Page

1128 / 1134

Location

United States

Related Subject Headings

  • Time Factors
  • Myocardial Infarction
  • Middle Aged
  • Male
  • Humans
  • Female
  • Electrocardiography
  • Coronary Disease
  • Coronary Circulation
  • Cardiovascular System & Hematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Quigley, P. J., Hinohara, T., Phillips, H. R., Peter, R. H., Behar, V. S., Kong, Y., … Stack, R. S. (1988). Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans. Circulation, 78(5 Pt 1), 1128–1134. https://doi.org/10.1161/01.cir.78.5.1128
Quigley, P. J., T. Hinohara, H. R. Phillips, R. H. Peter, V. S. Behar, Y. Kong, C. A. Simonton, J. A. Perez, and R. S. Stack. “Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.Circulation 78, no. 5 Pt 1 (November 1988): 1128–34. https://doi.org/10.1161/01.cir.78.5.1128.
Quigley PJ, Hinohara T, Phillips HR, Peter RH, Behar VS, Kong Y, et al. Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans. Circulation. 1988 Nov;78(5 Pt 1):1128–34.
Quigley, P. J., et al. “Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.Circulation, vol. 78, no. 5 Pt 1, Nov. 1988, pp. 1128–34. Pubmed, doi:10.1161/01.cir.78.5.1128.
Quigley PJ, Hinohara T, Phillips HR, Peter RH, Behar VS, Kong Y, Simonton CA, Perez JA, Stack RS. Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans. Circulation. 1988 Nov;78(5 Pt 1):1128–1134.

Published In

Circulation

DOI

ISSN

0009-7322

Publication Date

November 1988

Volume

78

Issue

5 Pt 1

Start / End Page

1128 / 1134

Location

United States

Related Subject Headings

  • Time Factors
  • Myocardial Infarction
  • Middle Aged
  • Male
  • Humans
  • Female
  • Electrocardiography
  • Coronary Disease
  • Coronary Circulation
  • Cardiovascular System & Hematology