Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.
Publication
, Journal Article
Woodard, PK; Patz, EF; Sostman, HD
Published in: J Comput Assist Tomogr
1992
Pseudoaneurysm at the aortic cannulation site is a rare but potentially fatal complication of coronary artery bypass surgery. We present two cases in which MRI provided significant information regarding the anatomy and extent of a pseudoaneurysm. In one case both spin-echo imaging and cine MRI with and without gradient moment nulling (flow compensation) were used. The absence of gradient moment nulling in cine MRI provides additional contrast between flowing and static blood. This contrast may complement conventional cine images with gradient moment nulling, providing further information.
Duke Scholars
Published In
J Comput Assist Tomogr
DOI
ISSN
0363-8715
Publication Date
1992
Volume
16
Issue
6
Start / End Page
883 / 887
Location
United States
Related Subject Headings
- Thrombosis
- Regional Blood Flow
- Nuclear Medicine & Medical Imaging
- Motion Pictures
- Male
- Magnetic Resonance Imaging
- Humans
- Coronary Artery Bypass
- Catheterization
- Blood Flow Velocity
Citation
APA
Chicago
ICMJE
MLA
NLM
Woodard, P. K., Patz, E. F., & Sostman, H. D. (1992). Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. J Comput Assist Tomogr, 16(6), 883–887. https://doi.org/10.1097/00004728-199211000-00010
Woodard, P. K., E. F. Patz, and H. D. Sostman. “Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.” J Comput Assist Tomogr 16, no. 6 (1992): 883–87. https://doi.org/10.1097/00004728-199211000-00010.
Woodard PK, Patz EF, Sostman HD. Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. J Comput Assist Tomogr. 1992;16(6):883–7.
Woodard, P. K., et al. “Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.” J Comput Assist Tomogr, vol. 16, no. 6, 1992, pp. 883–87. Pubmed, doi:10.1097/00004728-199211000-00010.
Woodard PK, Patz EF, Sostman HD. Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. J Comput Assist Tomogr. 1992;16(6):883–887.
Published In
J Comput Assist Tomogr
DOI
ISSN
0363-8715
Publication Date
1992
Volume
16
Issue
6
Start / End Page
883 / 887
Location
United States
Related Subject Headings
- Thrombosis
- Regional Blood Flow
- Nuclear Medicine & Medical Imaging
- Motion Pictures
- Male
- Magnetic Resonance Imaging
- Humans
- Coronary Artery Bypass
- Catheterization
- Blood Flow Velocity