Skip to main content

Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.

Publication ,  Journal Article
Woodard, PK; Patz, EF; Sostman, HD
Published in: J Comput Assist Tomogr
1992

Pseudoaneurysm at the aortic cannulation site is a rare but potentially fatal complication of coronary artery bypass surgery. We present two cases in which MRI provided significant information regarding the anatomy and extent of a pseudoaneurysm. In one case both spin-echo imaging and cine MRI with and without gradient moment nulling (flow compensation) were used. The absence of gradient moment nulling in cine MRI provides additional contrast between flowing and static blood. This contrast may complement conventional cine images with gradient moment nulling, providing further information.

Duke Scholars

Published In

J Comput Assist Tomogr

DOI

ISSN

0363-8715

Publication Date

1992

Volume

16

Issue

6

Start / End Page

883 / 887

Location

United States

Related Subject Headings

  • Thrombosis
  • Regional Blood Flow
  • Nuclear Medicine & Medical Imaging
  • Motion Pictures
  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Coronary Artery Bypass
  • Catheterization
  • Blood Flow Velocity
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Woodard, P. K., Patz, E. F., & Sostman, H. D. (1992). Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. J Comput Assist Tomogr, 16(6), 883–887. https://doi.org/10.1097/00004728-199211000-00010
Woodard, P. K., E. F. Patz, and H. D. Sostman. “Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.J Comput Assist Tomogr 16, no. 6 (1992): 883–87. https://doi.org/10.1097/00004728-199211000-00010.
Woodard PK, Patz EF, Sostman HD. Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. J Comput Assist Tomogr. 1992;16(6):883–7.
Woodard, P. K., et al. “Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.J Comput Assist Tomogr, vol. 16, no. 6, 1992, pp. 883–87. Pubmed, doi:10.1097/00004728-199211000-00010.
Woodard PK, Patz EF, Sostman HD. Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. J Comput Assist Tomogr. 1992;16(6):883–887.

Published In

J Comput Assist Tomogr

DOI

ISSN

0363-8715

Publication Date

1992

Volume

16

Issue

6

Start / End Page

883 / 887

Location

United States

Related Subject Headings

  • Thrombosis
  • Regional Blood Flow
  • Nuclear Medicine & Medical Imaging
  • Motion Pictures
  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Coronary Artery Bypass
  • Catheterization
  • Blood Flow Velocity