Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia.

Publication ,  Journal Article
Weinstein, MP; Mirrett, S; Reller, LB
Published in: J Clin Microbiol
May 1988

The Oxoid Signal (Oxoid U.S.A., Inc., Columbia, Md.) blood culture system is a newly described, innovative method for visually detecting growth of microorganisms (D. Sawney, S. Hinder, D. Swaine, and E.Y. Bridson, J. Clin. Pathol. 39:1259-1263, 1986). We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC (Johnson Laboratories, Towson, Md.) radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilus species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi.

Duke Scholars

Published In

J Clin Microbiol

DOI

ISSN

0095-1137

Publication Date

May 1988

Volume

26

Issue

5

Start / End Page

962 / 964

Location

United States

Related Subject Headings

  • Sepsis
  • Radiometry
  • Mycoses
  • Microbiology
  • Humans
  • Fungi
  • Bacteria
  • 3207 Medical microbiology
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Weinstein, M. P., Mirrett, S., & Reller, L. B. (1988). Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia. J Clin Microbiol, 26(5), 962–964. https://doi.org/10.1128/jcm.26.5.962-964.1988
Weinstein, M. P., S. Mirrett, and L. B. Reller. “Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia.J Clin Microbiol 26, no. 5 (May 1988): 962–64. https://doi.org/10.1128/jcm.26.5.962-964.1988.
Weinstein, M. P., et al. “Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia.J Clin Microbiol, vol. 26, no. 5, May 1988, pp. 962–64. Pubmed, doi:10.1128/jcm.26.5.962-964.1988.

Published In

J Clin Microbiol

DOI

ISSN

0095-1137

Publication Date

May 1988

Volume

26

Issue

5

Start / End Page

962 / 964

Location

United States

Related Subject Headings

  • Sepsis
  • Radiometry
  • Mycoses
  • Microbiology
  • Humans
  • Fungi
  • Bacteria
  • 3207 Medical microbiology
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences