Skip to main content
Journal cover image

MR microscopy at 7.0 T: effects of brain iron.

Publication ,  Journal Article
Malisch, TW; Hedlund, LW; Suddarth, SA; Johnson, GA
Published in: J Magn Reson Imaging
1991

The T2 of brain tissue is known to be field dependent, decreasing as B0 increases. Previous studies have attributed reduced T2 in the structures of the extrapyramidal motor system (EPMS) to high iron concentrations. The present study was designed to manipulate physiologic iron concentrations and study the effects on T2 and on the field dependence of T2 at 7.0 T in whole formalin-fixed brains. A rat model was devised in which iron concentrations in the structures of interest were altered by diet manipulation. Cerebral structures with different iron content were imaged and T2 measured with MR microscopy at both 2.0 and 7.0 T. T2 of all tissues was shorter by 40%-60% at 7.0 T. Although some dependence of T2 on iron concentration was evident, it was less than expected. The strongest correlation was in the substantia nigra. The highest-resolution studies, at 30 x 30 x 50 microns, show the myelin bundles in many of the EPMS structures but not in the substantia nigra. From these data, it appears that T2 at greater field strengths depends more on susceptibility-induced spin dephasing imposed by diffusion through the tissue microstructure than on the presence of iron.

Duke Scholars

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

1991

Volume

1

Issue

3

Start / End Page

301 / 305

Location

United States

Related Subject Headings

  • Substantia Nigra
  • Rats, Inbred Strains
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Iron
  • Extrapyramidal Tracts
  • Brain Chemistry
  • Animals
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Malisch, T. W., Hedlund, L. W., Suddarth, S. A., & Johnson, G. A. (1991). MR microscopy at 7.0 T: effects of brain iron. J Magn Reson Imaging, 1(3), 301–305. https://doi.org/10.1002/jmri.1880010308
Malisch, T. W., L. W. Hedlund, S. A. Suddarth, and G. A. Johnson. “MR microscopy at 7.0 T: effects of brain iron.J Magn Reson Imaging 1, no. 3 (1991): 301–5. https://doi.org/10.1002/jmri.1880010308.
Malisch TW, Hedlund LW, Suddarth SA, Johnson GA. MR microscopy at 7.0 T: effects of brain iron. J Magn Reson Imaging. 1991;1(3):301–5.
Malisch, T. W., et al. “MR microscopy at 7.0 T: effects of brain iron.J Magn Reson Imaging, vol. 1, no. 3, 1991, pp. 301–05. Pubmed, doi:10.1002/jmri.1880010308.
Malisch TW, Hedlund LW, Suddarth SA, Johnson GA. MR microscopy at 7.0 T: effects of brain iron. J Magn Reson Imaging. 1991;1(3):301–305.
Journal cover image

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

1991

Volume

1

Issue

3

Start / End Page

301 / 305

Location

United States

Related Subject Headings

  • Substantia Nigra
  • Rats, Inbred Strains
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Iron
  • Extrapyramidal Tracts
  • Brain Chemistry
  • Animals
  • 3202 Clinical sciences