Skip to main content
Journal cover image

A fast spin echo technique with circular sampling.

Publication ,  Journal Article
Zhou, X; Liang, ZP; Gewalt, SL; Cofer, GP; Lauterbur, PC; Johnson, GA
Published in: Magn Reson Med
January 1998

This paper presents a fast spin echo (FSE) imaging method that employs circular sampling of k-space. The technique has been implemented on a 2 Tesla imaging system and validated on both phantoms and living animals. Experimental studies have shown that circular sampling can produce artifact-free FSE images without the need of phase correction. Although not fully explored, preliminary results also show that circular sampling may have advantages over the conventional rectilinear FSE in signal-to-noise ratio and imaging efficiency. A major disadvantage is the increased sensitivity to off-resonance effects. The authors expect that the FSE technique with circular sampling will find its applications in magnetic resonance microscopy, neuro-functional imaging, and real-time dynamic studies.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

January 1998

Volume

39

Issue

1

Start / End Page

23 / 27

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Rats
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Models, Theoretical
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Echo-Planar Imaging
  • Brain
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhou, X., Liang, Z. P., Gewalt, S. L., Cofer, G. P., Lauterbur, P. C., & Johnson, G. A. (1998). A fast spin echo technique with circular sampling. Magn Reson Med, 39(1), 23–27. https://doi.org/10.1002/mrm.1910390106
Zhou, X., Z. P. Liang, S. L. Gewalt, G. P. Cofer, P. C. Lauterbur, and G. A. Johnson. “A fast spin echo technique with circular sampling.Magn Reson Med 39, no. 1 (January 1998): 23–27. https://doi.org/10.1002/mrm.1910390106.
Zhou X, Liang ZP, Gewalt SL, Cofer GP, Lauterbur PC, Johnson GA. A fast spin echo technique with circular sampling. Magn Reson Med. 1998 Jan;39(1):23–7.
Zhou, X., et al. “A fast spin echo technique with circular sampling.Magn Reson Med, vol. 39, no. 1, Jan. 1998, pp. 23–27. Pubmed, doi:10.1002/mrm.1910390106.
Zhou X, Liang ZP, Gewalt SL, Cofer GP, Lauterbur PC, Johnson GA. A fast spin echo technique with circular sampling. Magn Reson Med. 1998 Jan;39(1):23–27.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

January 1998

Volume

39

Issue

1

Start / End Page

23 / 27

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Rats
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Models, Theoretical
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Echo-Planar Imaging
  • Brain
  • Animals