T1 rho relaxation and its application to MR histology.

Publication ,  Journal Article
Engelhardt, RT; Johnson, GA
Published in: Magn Reson Med
May 1996

The application of T1 rho an an alternative contrast parameter in high-field magnetic resonance histology (MRH) has been investigated. Spectroscopic measurements of T1 rho were performed on 5.75% agar and 1.0 mM MnCI2 phantoms at 9.4 T to validate the accuracy of the imaging measurements. Image studies were performed at 2.0 and 9.4 T on perfusion-fixed 17.5-day-old mouse embryos. T1, T2, and T1 rho relaxation times were calculated for the phantoms and muscle, diencephalon, and liver tissues. The 5.75% agar phantom and all tissues showed T1 rho dispersion with B1L, whereas the 1.0 mM MnCI2 phantom showed no significant B1L dependence. T1 rho dispersion with B(O) was observed arising from the effects of diffusion through susceptibility-induced gradients. T1 rho shows promise as a contrast parameter in high-field MRH because it is capable of producing T2-like contrast without the susceptibility artifacts associated with T2-weighted images.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

May 1996

Volume

35

Issue

5

Start / End Page

781 / 786

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Microscopy
  • Mice
  • Magnetic Resonance Spectroscopy
  • Magnetic Resonance Imaging
  • Image Enhancement
  • Histological Techniques
  • Female
  • Embryo, Mammalian
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Engelhardt, R. T., & Johnson, G. A. (1996). T1 rho relaxation and its application to MR histology. Magn Reson Med, 35(5), 781–786. https://doi.org/10.1002/mrm.1910350520
Engelhardt, R. T., and G. A. Johnson. “T1 rho relaxation and its application to MR histology.Magn Reson Med 35, no. 5 (May 1996): 781–86. https://doi.org/10.1002/mrm.1910350520.
Engelhardt RT, Johnson GA. T1 rho relaxation and its application to MR histology. Magn Reson Med. 1996 May;35(5):781–6.
Engelhardt, R. T., and G. A. Johnson. “T1 rho relaxation and its application to MR histology.Magn Reson Med, vol. 35, no. 5, May 1996, pp. 781–86. Pubmed, doi:10.1002/mrm.1910350520.
Engelhardt RT, Johnson GA. T1 rho relaxation and its application to MR histology. Magn Reson Med. 1996 May;35(5):781–786.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

May 1996

Volume

35

Issue

5

Start / End Page

781 / 786

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Microscopy
  • Mice
  • Magnetic Resonance Spectroscopy
  • Magnetic Resonance Imaging
  • Image Enhancement
  • Histological Techniques
  • Female
  • Embryo, Mammalian