Skip to main content
Journal cover image

Relaxation measurements at 300 MHz using MR microscopy.

Publication ,  Journal Article
Dockery, SE; Suddarth, SA; Johnson, GA
Published in: Magn Reson Med
August 1989

Previous data on changes in tissue T1 with field have suggested the convergence of tissue T1 values toward a common value at high (greater than 4.0 T) fields. Measures of T2 dependence have suggested reduction of T2 with field. The purpose of this study was to observe the T1 and T2 at 85.5 and 300 MHz of microstructures in excised rat kidneys by employing MR microscopy. This study represents the first attempt of MR microscopy at 7.0 T with regard to the subject of magnetic field dependence of T1 and T2. As expected, T1 did increase with increasing field strength but not as dramatically as might be expected. Subtle differences in the microstructures of the kidney and the binding of water in those structures were discernible on the basis of T1 differences at 300 MHz. T2 values decreased, raising speculation concerning the mechanism for this dependence. The improved SNR permits smaller samples to be examined at much higher resolutions (greater than 30 X 30 X 200 microns), further extending the potentials for MR microscopy.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

August 1989

Volume

11

Issue

2

Start / End Page

182 / 192

Location

United States

Related Subject Headings

  • Rats, Inbred F344
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Microscopy
  • Magnetic Resonance Imaging
  • Kidney
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dockery, S. E., Suddarth, S. A., & Johnson, G. A. (1989). Relaxation measurements at 300 MHz using MR microscopy. Magn Reson Med, 11(2), 182–192. https://doi.org/10.1002/mrm.1910110206
Dockery, S. E., S. A. Suddarth, and G. A. Johnson. “Relaxation measurements at 300 MHz using MR microscopy.Magn Reson Med 11, no. 2 (August 1989): 182–92. https://doi.org/10.1002/mrm.1910110206.
Dockery SE, Suddarth SA, Johnson GA. Relaxation measurements at 300 MHz using MR microscopy. Magn Reson Med. 1989 Aug;11(2):182–92.
Dockery, S. E., et al. “Relaxation measurements at 300 MHz using MR microscopy.Magn Reson Med, vol. 11, no. 2, Aug. 1989, pp. 182–92. Pubmed, doi:10.1002/mrm.1910110206.
Dockery SE, Suddarth SA, Johnson GA. Relaxation measurements at 300 MHz using MR microscopy. Magn Reson Med. 1989 Aug;11(2):182–192.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

August 1989

Volume

11

Issue

2

Start / End Page

182 / 192

Location

United States

Related Subject Headings

  • Rats, Inbred F344
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Microscopy
  • Magnetic Resonance Imaging
  • Kidney
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering