Skip to main content
Journal cover image

Mixing oxygen with hyperpolarized (3)He for small-animal lung studies.

Publication ,  Journal Article
Hedlund, LW; Möller, HE; Chen, XJ; Chawla, MS; Cofer, GP; Johnson, GA
Published in: NMR Biomed
June 2000

Hyperpolarized helium (HP (3)He) is useful for direct MR imaging of the gas spaces of small animal lungs. Previously, breaths of 100% HP (3)He were alternated with breaths of air to maximize helium signal in the lungs and to minimize the depolarizing effects of O(2). However, for high-resolution imaging requiring many HP (3)He breaths (hundreds) and for pulmonary disease studies, a method was needed to simultaneously deliver O(2) and HP (3)He with each breath without significant loss of polarization. We modified our existing computer-controlled ventilator by adding a plastic valve, additional relays and a controller. O(2) and HP (3)He are mixed at the beginning of each breath within the body of a breathing valve, which is attached directly to the endotracheal tube. With this mixing method, we found that T(1) relaxation of HP (3)He in the guinea pig lung was about 20 s compared to 30 s with alternate air/HP (3)He breathing. Because imaging times during each breath are short (about 500 ms), the HP (3)He signal loss from O(2) contact is calculated to be less than 5%. We concluded that the advantages of mixing HP (3)He with O(2), such as shorter imaging times (reduced T(1) losses in reservoir) and improved physiologic stability, outweigh the small signal loss from the depolarizing effects of oxygen on HP (3)He.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

NMR Biomed

DOI

ISSN

0952-3480

Publication Date

June 2000

Volume

13

Issue

4

Start / End Page

202 / 206

Location

England

Related Subject Headings

  • Respiratory Function Tests
  • Rats
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Lung
  • Isotopes
  • Intubation, Intratracheal
  • Helium
  • Animals, Laboratory
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hedlund, L. W., Möller, H. E., Chen, X. J., Chawla, M. S., Cofer, G. P., & Johnson, G. A. (2000). Mixing oxygen with hyperpolarized (3)He for small-animal lung studies. NMR Biomed, 13(4), 202–206. https://doi.org/10.1002/1099-1492(200006)13:4<202::aid-nbm645>3.0.co;2-j
Hedlund, L. W., H. E. Möller, X. J. Chen, M. S. Chawla, G. P. Cofer, and G. A. Johnson. “Mixing oxygen with hyperpolarized (3)He for small-animal lung studies.NMR Biomed 13, no. 4 (June 2000): 202–6. https://doi.org/10.1002/1099-1492(200006)13:4<202::aid-nbm645>3.0.co;2-j.
Hedlund LW, Möller HE, Chen XJ, Chawla MS, Cofer GP, Johnson GA. Mixing oxygen with hyperpolarized (3)He for small-animal lung studies. NMR Biomed. 2000 Jun;13(4):202–6.
Hedlund, L. W., et al. “Mixing oxygen with hyperpolarized (3)He for small-animal lung studies.NMR Biomed, vol. 13, no. 4, June 2000, pp. 202–06. Pubmed, doi:10.1002/1099-1492(200006)13:4<202::aid-nbm645>3.0.co;2-j.
Hedlund LW, Möller HE, Chen XJ, Chawla MS, Cofer GP, Johnson GA. Mixing oxygen with hyperpolarized (3)He for small-animal lung studies. NMR Biomed. 2000 Jun;13(4):202–206.
Journal cover image

Published In

NMR Biomed

DOI

ISSN

0952-3480

Publication Date

June 2000

Volume

13

Issue

4

Start / End Page

202 / 206

Location

England

Related Subject Headings

  • Respiratory Function Tests
  • Rats
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Lung
  • Isotopes
  • Intubation, Intratracheal
  • Helium
  • Animals, Laboratory