Skip to main content
Journal cover image

Reduction of ringing and blurring artifacts in fast spin-echo imaging.

Publication ,  Journal Article
Zhou, X; Liang, ZP; Cofer, GP; Beaulieu, CF; Suddarth, SA; Johnson, GA
Published in: J Magn Reson Imaging
1993

A simple method was devised to reduce ringing and blurring artifacts caused by discontinuous T2 weighting of k-space data in fast spin-echo magnetic resonance (MR) imaging. The method demodulates the weighting function along the phase-encoding direction by using multiple T2 values derived from a set of non-phase-encoded echoes obtained from an extra excitation. The performance of this method was evaluated by computer simulations and experiments, which confirmed its capability of effectively reducing or, in some cases, even completely removing the ringing and blurring artifacts. The results also show that the proposed method produces better results than other artifact reduction methods. The method is particularly useful at high magnetic field strengths (7.1-9.4 T) and with strong gradients (> 20 G/cm) used in MR microscopy, in which the apparent T2 values are short for most tissues. The authors expect that the proposed method will find useful applications in various fast spin-echo pulse sequences.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

1993

Volume

3

Issue

5

Start / End Page

803 / 807

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Models, Structural
  • Magnetic Resonance Imaging
  • Image Enhancement
  • Artifacts
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
  • 09 Engineering
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhou, X., Liang, Z. P., Cofer, G. P., Beaulieu, C. F., Suddarth, S. A., & Johnson, G. A. (1993). Reduction of ringing and blurring artifacts in fast spin-echo imaging. J Magn Reson Imaging, 3(5), 803–807. https://doi.org/10.1002/jmri.1880030518
Zhou, X., Z. P. Liang, G. P. Cofer, C. F. Beaulieu, S. A. Suddarth, and G. A. Johnson. “Reduction of ringing and blurring artifacts in fast spin-echo imaging.J Magn Reson Imaging 3, no. 5 (1993): 803–7. https://doi.org/10.1002/jmri.1880030518.
Zhou X, Liang ZP, Cofer GP, Beaulieu CF, Suddarth SA, Johnson GA. Reduction of ringing and blurring artifacts in fast spin-echo imaging. J Magn Reson Imaging. 1993;3(5):803–7.
Zhou, X., et al. “Reduction of ringing and blurring artifacts in fast spin-echo imaging.J Magn Reson Imaging, vol. 3, no. 5, 1993, pp. 803–07. Pubmed, doi:10.1002/jmri.1880030518.
Zhou X, Liang ZP, Cofer GP, Beaulieu CF, Suddarth SA, Johnson GA. Reduction of ringing and blurring artifacts in fast spin-echo imaging. J Magn Reson Imaging. 1993;3(5):803–807.
Journal cover image

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

1993

Volume

3

Issue

5

Start / End Page

803 / 807

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Models, Structural
  • Magnetic Resonance Imaging
  • Image Enhancement
  • Artifacts
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
  • 09 Engineering
  • 02 Physical Sciences