Skip to main content
Journal cover image

Functional MR microscopy of the lung using hyperpolarized 3He.

Publication ,  Journal Article
Viallon, M; Cofer, GP; Suddarth, SA; Möller, HE; Chen, XJ; Chawla, MS; Hedlund, LW; Crémillieux, Y; Johnson, GA
Published in: Magn Reson Med
April 1999

A new strategy designed to provide functional magnetic resonance images of the lung in small animals at microscopic resolution using hyperpolarized 3He is described. The pulse sequence is based on a combination of radial acquisition (RA) and CINE techniques, referred to as RA-CINE, and is designed for use with hyperpolarized 3He to explore lung ventilation with high temporal and spatial resolution in small animal models. Ventilation of the live guinea pig is demonstrated with effective temporal resolution of 50 msec and in-plane spatial resolution of <100 microm using hyperpolarized 3He. The RA-CINE sequence allows one to follow gas inflow and outflow in the airways as well as in the distal part of the lungs. Regional analysis of signal intensity variations can be performed and can help assess functional lung parameters such as residual gas volume and lung compliance to gas inflow.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

April 1999

Volume

41

Issue

4

Start / End Page

787 / 792

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Microscopy
  • Magnetic Resonance Imaging, Cine
  • Lung
  • Isotopes
  • Helium
  • Guinea Pigs
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Viallon, M., Cofer, G. P., Suddarth, S. A., Möller, H. E., Chen, X. J., Chawla, M. S., … Johnson, G. A. (1999). Functional MR microscopy of the lung using hyperpolarized 3He. Magn Reson Med, 41(4), 787–792. https://doi.org/10.1002/(sici)1522-2594(199904)41:4<787::aid-mrm18>3.0.co;2-4
Viallon, M., G. P. Cofer, S. A. Suddarth, H. E. Möller, X. J. Chen, M. S. Chawla, L. W. Hedlund, Y. Crémillieux, and G. A. Johnson. “Functional MR microscopy of the lung using hyperpolarized 3He.Magn Reson Med 41, no. 4 (April 1999): 787–92. https://doi.org/10.1002/(sici)1522-2594(199904)41:4<787::aid-mrm18>3.0.co;2-4.
Viallon M, Cofer GP, Suddarth SA, Möller HE, Chen XJ, Chawla MS, et al. Functional MR microscopy of the lung using hyperpolarized 3He. Magn Reson Med. 1999 Apr;41(4):787–92.
Viallon, M., et al. “Functional MR microscopy of the lung using hyperpolarized 3He.Magn Reson Med, vol. 41, no. 4, Apr. 1999, pp. 787–92. Pubmed, doi:10.1002/(sici)1522-2594(199904)41:4<787::aid-mrm18>3.0.co;2-4.
Viallon M, Cofer GP, Suddarth SA, Möller HE, Chen XJ, Chawla MS, Hedlund LW, Crémillieux Y, Johnson GA. Functional MR microscopy of the lung using hyperpolarized 3He. Magn Reson Med. 1999 Apr;41(4):787–792.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

April 1999

Volume

41

Issue

4

Start / End Page

787 / 792

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Microscopy
  • Magnetic Resonance Imaging, Cine
  • Lung
  • Isotopes
  • Helium
  • Guinea Pigs
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering