Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution.

Publication ,  Journal Article
Sherwood, A; Carter, LS; Murphy, CA
Published in: Aviat Space Environ Med
February 1991

One critical component of the Kubicek (8) stroke volume equation, used to measure cardiac output by impedance cardiography, is dZ/dt(max). The present study, conducted on six anesthetized dogs, compared impedance cardiac output derived using two alternative methods of quantifying dZ/dt(max), with simultaneous thermodilution measures. Values for dZ/dt(max) quantified relative to dZ/dt = 0 baseline and relative to the dZ/dt B-point were entered into the Kubicek equation to generate cardiac output measures designated as impedance-A and impedance-B, respectively. Emphasis was placed upon evaluating impedance cardiac output within its accepted limits as a relative change measure. Systematic alterations in cardiac output were produced by intravenously administered isoproterenol, phenylephrine and nitroprusside. Drug-induced changes in cardiac output measured by the impedance-A method were statistically identical to thermodilution. For the impedance-B method, similarity to thermodilution was limited to two of the three drug conditions. Correlations of impedance cardiac output with thermodilution tended to be higher for the impedance-A method. Together with theoretical and practical considerations, these results support quantification of dZ/dt(max) relative to dZ/dt = 0 when used in the Kubicek stroke volume equation.

Duke Scholars

Published In

Aviat Space Environ Med

ISSN

0095-6562

Publication Date

February 1991

Volume

62

Issue

2

Start / End Page

116 / 122

Location

United States

Related Subject Headings

  • Thermodilution
  • Stroke Volume
  • Physiology
  • Phenylephrine
  • Nitroprusside
  • Isoproterenol
  • Heart Rate
  • Dogs
  • Cardiography, Impedance
  • Cardiac Output
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Sherwood, A., Carter, L. S., & Murphy, C. A. (1991). Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution. Aviat Space Environ Med, 62(2), 116–122.
Sherwood, A., L. S. Carter, and C. A. Murphy. “Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution.Aviat Space Environ Med 62, no. 2 (February 1991): 116–22.
Sherwood A, Carter LS, Murphy CA. Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution. Aviat Space Environ Med. 1991 Feb;62(2):116–22.
Sherwood, A., et al. “Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution.Aviat Space Environ Med, vol. 62, no. 2, Feb. 1991, pp. 116–22.
Sherwood A, Carter LS, Murphy CA. Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution. Aviat Space Environ Med. 1991 Feb;62(2):116–122.

Published In

Aviat Space Environ Med

ISSN

0095-6562

Publication Date

February 1991

Volume

62

Issue

2

Start / End Page

116 / 122

Location

United States

Related Subject Headings

  • Thermodilution
  • Stroke Volume
  • Physiology
  • Phenylephrine
  • Nitroprusside
  • Isoproterenol
  • Heart Rate
  • Dogs
  • Cardiography, Impedance
  • Cardiac Output