Skip to main content
Journal cover image

A method of MRI-based thermal modelling for a RF phased array.

Publication ,  Journal Article
Das, SK; Jones, EA; Samulski, TV
Published in: Int J Hyperthermia
2001

Magnetic Resonance Imaging (MRI) is an attractive method of temperature monitoring in vivo due to its non-invasive nature. The natural extension of this temperature monitoring is to implement temperature control. This work outlines a method of MRI-based thermal modelling for multi-source phased array heating systems that can potentially be employed, in the future, for real time temperature prediction and control. This method is based on Pennes bioheat equation. It employs the superposition of an empirically acquired basis set of temperature distributions that define the heating system's temperature response. MR thermal images based on the proton resonance frequency shift (PRFS) technique are used to acquire this basis set. The feasibility of this approach is tested in phantom using a radiofrequency (RF) heating system. The results show that this method can accurately reproduce measured temperature distributions outside of the basis set.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Int J Hyperthermia

DOI

ISSN

0265-6736

Publication Date

2001

Volume

17

Issue

6

Start / End Page

465 / 482

Location

England

Related Subject Headings

  • Thermometers
  • Radiofrequency Therapy
  • Phantoms, Imaging
  • Oncology & Carcinogenesis
  • Monitoring, Physiologic
  • Models, Biological
  • Magnetic Resonance Imaging
  • In Vitro Techniques
  • Image Processing, Computer-Assisted
  • Hyperthermia, Induced
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Das, S. K., Jones, E. A., & Samulski, T. V. (2001). A method of MRI-based thermal modelling for a RF phased array. Int J Hyperthermia, 17(6), 465–482. https://doi.org/10.1080/02656730110068320
Das, S. K., E. A. Jones, and T. V. Samulski. “A method of MRI-based thermal modelling for a RF phased array.Int J Hyperthermia 17, no. 6 (2001): 465–82. https://doi.org/10.1080/02656730110068320.
Das SK, Jones EA, Samulski TV. A method of MRI-based thermal modelling for a RF phased array. Int J Hyperthermia. 2001;17(6):465–82.
Das, S. K., et al. “A method of MRI-based thermal modelling for a RF phased array.Int J Hyperthermia, vol. 17, no. 6, 2001, pp. 465–82. Pubmed, doi:10.1080/02656730110068320.
Das SK, Jones EA, Samulski TV. A method of MRI-based thermal modelling for a RF phased array. Int J Hyperthermia. 2001;17(6):465–482.
Journal cover image

Published In

Int J Hyperthermia

DOI

ISSN

0265-6736

Publication Date

2001

Volume

17

Issue

6

Start / End Page

465 / 482

Location

England

Related Subject Headings

  • Thermometers
  • Radiofrequency Therapy
  • Phantoms, Imaging
  • Oncology & Carcinogenesis
  • Monitoring, Physiologic
  • Models, Biological
  • Magnetic Resonance Imaging
  • In Vitro Techniques
  • Image Processing, Computer-Assisted
  • Hyperthermia, Induced