Skip to main content

Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy.

Publication ,  Journal Article
Miften, MM; Das, SK; Shafman, TD; Marks, LB
Published in: Med Phys
December 2002

A steepest-descent gradient algorithm is developed to optimize the stepping of a 90Sr/90Y radiation source train (RST) for intravascular brachytherapy (IVB). The objective function is to deliver a uniform dose in a coronary target vessel and minimize the dose in adjacent normal vessel tissue at the proximal and distal edges of the coronary target vessel. Based on the target length and number of dwell points (number of steps), the algorithm modulates the dwell times and corresponding dwell positions that optimize the weighted addition of staggered EGS4 Monte Carlo (MC) calculated dose distribution from a single RST. Stepping treatment plans are generated for target vessel lengths of 3.0, 3.3, and 3.8 cm. For both the unoptimized and optimized plans, the dose heterogeneity in the target vessel wall, and length of nontarget vessel receiving 3 Gy, is assessed to compare plans. Optimization results show a 14% dose uniformity within the target is achievable for all vessel lengths. Further, the dose in the adjacent normal tissue is lower in the optimized plans than the unoptimized plans. The work presented in this paper provides a model to address the finite length of RST in IVB treatments. While the results presented are specific to the 90Sr/90Y RST, the methods should apply to other finite length RSTs.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

December 2002

Volume

29

Issue

12

Start / End Page

2891 / 2896

Location

United States

Related Subject Headings

  • Yttrium Radioisotopes
  • Strontium Radioisotopes
  • Radiotherapy Planning, Computer-Assisted
  • Radiometry
  • Radioisotopes
  • Nuclear Medicine & Medical Imaging
  • Monte Carlo Method
  • Humans
  • Computer Simulation
  • Cardiovascular Diseases
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Miften, M. M., Das, S. K., Shafman, T. D., & Marks, L. B. (2002). Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy. Med Phys, 29(12), 2891–2896. https://doi.org/10.1118/1.1524169
Miften, Moyed M., Shiva K. Das, Timothy D. Shafman, and Lawrence B. Marks. “Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy.Med Phys 29, no. 12 (December 2002): 2891–96. https://doi.org/10.1118/1.1524169.
Miften MM, Das SK, Shafman TD, Marks LB. Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy. Med Phys. 2002 Dec;29(12):2891–6.
Miften, Moyed M., et al. “Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy.Med Phys, vol. 29, no. 12, Dec. 2002, pp. 2891–96. Pubmed, doi:10.1118/1.1524169.
Miften MM, Das SK, Shafman TD, Marks LB. Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy. Med Phys. 2002 Dec;29(12):2891–2896.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

December 2002

Volume

29

Issue

12

Start / End Page

2891 / 2896

Location

United States

Related Subject Headings

  • Yttrium Radioisotopes
  • Strontium Radioisotopes
  • Radiotherapy Planning, Computer-Assisted
  • Radiometry
  • Radioisotopes
  • Nuclear Medicine & Medical Imaging
  • Monte Carlo Method
  • Humans
  • Computer Simulation
  • Cardiovascular Diseases