Comparison of an enzyme-linked immunoassay and a quantitative indirect fluorescent-antibody test with the conventional indirect fluorescent-antibody test for detecting antibodies to Toxoplasma gondii.

Publication ,  Journal Article
Violand, SA; Mitchell, TG; Kleeman, KT
Published in: J Clin Microbiol
August 1982

Two new methods for the detection of antibodies to Toxoplasma gondii, an enzyme-linked immunosorbent assay and a quantitative immunofluorescence assay, were evaluated and compared with the conventional indirect fluorescent-antibody slide test. Each of 100 human sera was assayed twice by the three procedures. Both the enzyme-linked immunosorbent assay and the quantitative immunofluorescence assay correlated well with serologically positive (indirect fluorescent-antibody titer greater than or equal to 1:32) and negative sera. The enzyme-linked immunosorbent assay was more specific, but less sensitive, than the quantitative immunofluorescence assay. However, the quantitative immunofluorescence assay was more reproducible and more rapid than the enzyme-linked immunosorbent assay.

Duke Scholars

Published In

J Clin Microbiol

DOI

ISSN

0095-1137

Publication Date

August 1982

Volume

16

Issue

2

Start / End Page

341 / 344

Location

United States

Related Subject Headings

  • Toxoplasma
  • Microbiology
  • Humans
  • Fluorescent Antibody Technique
  • Evaluation Studies as Topic
  • Enzyme-Linked Immunosorbent Assay
  • Antibodies
  • Animals
  • 3207 Medical microbiology
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Violand, S. A., Mitchell, T. G., & Kleeman, K. T. (1982). Comparison of an enzyme-linked immunoassay and a quantitative indirect fluorescent-antibody test with the conventional indirect fluorescent-antibody test for detecting antibodies to Toxoplasma gondii. J Clin Microbiol, 16(2), 341–344. https://doi.org/10.1128/jcm.16.2.341-344.1982
Violand, S. A., T. G. Mitchell, and K. T. Kleeman. “Comparison of an enzyme-linked immunoassay and a quantitative indirect fluorescent-antibody test with the conventional indirect fluorescent-antibody test for detecting antibodies to Toxoplasma gondii.J Clin Microbiol 16, no. 2 (August 1982): 341–44. https://doi.org/10.1128/jcm.16.2.341-344.1982.

Published In

J Clin Microbiol

DOI

ISSN

0095-1137

Publication Date

August 1982

Volume

16

Issue

2

Start / End Page

341 / 344

Location

United States

Related Subject Headings

  • Toxoplasma
  • Microbiology
  • Humans
  • Fluorescent Antibody Technique
  • Evaluation Studies as Topic
  • Enzyme-Linked Immunosorbent Assay
  • Antibodies
  • Animals
  • 3207 Medical microbiology
  • 3202 Clinical sciences