Skip to main content

An assessment of the reliability of the Scoliometer.

Publication ,  Journal Article
Murrell, GA; Coonrad, RW; Moorman, CT; Fitch, RD
Published in: Spine (Phila Pa 1976)
May 1993

Accurate noninvasive measurements of spinal curvature are crucial in planning treatment and assessing curve progression in adolescent idiopathic scoliosis. An inter-rater agreement trial and an intrarater agreement trial were undertaken to estimate the reliability of axial rotation measurement using the Scoliometer (Orthopedic Systems, Inc., Haywood, California). In the inter-rater trial, two orthopedic surgeons and two orthopedic surgery residents independently measured the thoracic and lumbar axial rotations of 22 patients with idiopathic scoliosis using the Scoliometer. In the intrarater, trial a single orthopedic surgeon measured the thoracic and lumbar axial rotations of 25 patients on four separate occasions with the Scoliometer. Inter-rater agreement using the Scoliometer to estimate the magnitude of the hump (in centimeters) in the thoracic and lumbar regions was poor (intraclass correlation coefficient, Rho = 0.57 and Rho = 0.76 for the thoracic and lumbar regions, respectively). Inter-rater agreement using the Scoliometer to estimate the degree of axial trunk rotation was better (Rho = 0.81 and Rho = 0.82 for the thoracic and lumbar regions, respectively). Intrarater agreement using this device to estimate the magnitude of the hump (in centimeters) in the thoracic and lumbar regions was good (Rho = 0.90 and Rho = 0.84 for the thoracic and lumbar regions, respectively). Intrarater agreement using the Scoliometer to estimate the degrees of curvature was outstanding (Rho = 0.995 and Rho = 0.998 for the thoracic and lumbar regions, respectively). These results indicate that the Scoliometer can be a reliable noninvasive method for repetitively assessing spinal axial rotation when used by a single trained observer.

Duke Scholars

Published In

Spine (Phila Pa 1976)

DOI

ISSN

0362-2436

Publication Date

May 1993

Volume

18

Issue

6

Start / End Page

709 / 712

Location

United States

Related Subject Headings

  • Thoracic Vertebrae
  • Scoliosis
  • Reproducibility of Results
  • Orthopedics
  • Orthopedic Equipment
  • Observer Variation
  • Lumbar Vertebrae
  • Humans
  • Female
  • Evaluation Studies as Topic
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Murrell, G. A., Coonrad, R. W., Moorman, C. T., & Fitch, R. D. (1993). An assessment of the reliability of the Scoliometer. Spine (Phila Pa 1976), 18(6), 709–712. https://doi.org/10.1097/00007632-199305000-00006
Murrell, G. A., R. W. Coonrad, C. T. Moorman, and R. D. Fitch. “An assessment of the reliability of the Scoliometer.Spine (Phila Pa 1976) 18, no. 6 (May 1993): 709–12. https://doi.org/10.1097/00007632-199305000-00006.
Murrell GA, Coonrad RW, Moorman CT, Fitch RD. An assessment of the reliability of the Scoliometer. Spine (Phila Pa 1976). 1993 May;18(6):709–12.
Murrell, G. A., et al. “An assessment of the reliability of the Scoliometer.Spine (Phila Pa 1976), vol. 18, no. 6, May 1993, pp. 709–12. Pubmed, doi:10.1097/00007632-199305000-00006.
Murrell GA, Coonrad RW, Moorman CT, Fitch RD. An assessment of the reliability of the Scoliometer. Spine (Phila Pa 1976). 1993 May;18(6):709–712.

Published In

Spine (Phila Pa 1976)

DOI

ISSN

0362-2436

Publication Date

May 1993

Volume

18

Issue

6

Start / End Page

709 / 712

Location

United States

Related Subject Headings

  • Thoracic Vertebrae
  • Scoliosis
  • Reproducibility of Results
  • Orthopedics
  • Orthopedic Equipment
  • Observer Variation
  • Lumbar Vertebrae
  • Humans
  • Female
  • Evaluation Studies as Topic