Skip to main content
Journal cover image

Accuracy of radionuclide imaging in distinguishing renal masses from normal variants.

Publication ,  Journal Article
Older, RA; Korobkin, M; Workman, J; Cleeve, DM; Cleeve, LK; Sullivan, D; Webster, GD
Published in: Radiology
August 1980

To determine the accuracy of scintigraphy in distinguishing true renal masses from normal variants, 40 patients with excretory urographic findings indicating a possible, but not definite, mass lesion were studied. Scintigraphy correctly identified 17 true masses and 17 normal variants. Four false positive and two false negative results were obtained.

Duke Scholars

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

August 1980

Volume

136

Issue

2

Start / End Page

443 / 448

Location

United States

Related Subject Headings

  • Urography
  • Technetium
  • Radionuclide Imaging
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Kidney Neoplasms
  • Kidney Diseases, Cystic
  • Kidney Diseases
  • Kidney
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Older, R. A., Korobkin, M., Workman, J., Cleeve, D. M., Cleeve, L. K., Sullivan, D., & Webster, G. D. (1980). Accuracy of radionuclide imaging in distinguishing renal masses from normal variants. Radiology, 136(2), 443–448. https://doi.org/10.1148/radiology.136.2.7403523
Older, R. A., M. Korobkin, J. Workman, D. M. Cleeve, L. K. Cleeve, D. Sullivan, and G. D. Webster. “Accuracy of radionuclide imaging in distinguishing renal masses from normal variants.Radiology 136, no. 2 (August 1980): 443–48. https://doi.org/10.1148/radiology.136.2.7403523.
Older RA, Korobkin M, Workman J, Cleeve DM, Cleeve LK, Sullivan D, et al. Accuracy of radionuclide imaging in distinguishing renal masses from normal variants. Radiology. 1980 Aug;136(2):443–8.
Older, R. A., et al. “Accuracy of radionuclide imaging in distinguishing renal masses from normal variants.Radiology, vol. 136, no. 2, Aug. 1980, pp. 443–48. Pubmed, doi:10.1148/radiology.136.2.7403523.
Older RA, Korobkin M, Workman J, Cleeve DM, Cleeve LK, Sullivan D, Webster GD. Accuracy of radionuclide imaging in distinguishing renal masses from normal variants. Radiology. 1980 Aug;136(2):443–448.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

August 1980

Volume

136

Issue

2

Start / End Page

443 / 448

Location

United States

Related Subject Headings

  • Urography
  • Technetium
  • Radionuclide Imaging
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Kidney Neoplasms
  • Kidney Diseases, Cystic
  • Kidney Diseases
  • Kidney