The effect of cardiac compression on defibrillation efficacy and the upper limit of vulnerability.

Publication ,  Journal Article
Idriss, SF; Anstadt, MP; Anstadt, GL; Ideker, RE
Published in: J Cardiovasc Electrophysiol
May 1995

INTRODUCTION: We determined the effects of decreasing the ventricular blood volume and altering cardiac geometry on defibrillation, the upper limit of vulnerability (ULV), and the relationship between them. METHODS AND RESULTS: In six pigs, fibrillation/defibrillation trials were performed with a left ventricular apex patch to a superior vena cava catheter electrode configuration and a biphasic waveform. Thirty trials each were performed on a compressed versus noncompressed (normal) heart. Compression was achieved using direct mechanical ventricular actuation. Dose-response curves were constructed, and the 50% probability points (ED50) were compared for leading edge voltage (LEV), leading edge current (LEI), and total energy (TE). In another 12 pigs, triplicate defibrillation thresholds (DFTs) and ULVs were determined for each heart state. The T wave was scanned with shocks in 10-msec steps for determining the ULV. Compression resulted in decreased ED50s for LEV (delta = 138 +/- 77 V, P < 0.05, mean +/- SD), LEI (delta = 1.57 +/- 0.7 A, P < 0.05), and TE (delta = 4.9 +/- 3.6 J, P < 0.05) compared to normal. In the second study, compression significantly reduced DFT (P < 0.02) and ULV (P < 0.02) for LEV, LEI, and TE compared to normal. The ULV tended to be lower than the DFT for the normal heart state (delta = 23 +/- 46 V LEV: P = NS). However, the ULV was significantly greater than the DFT for the compressed heart state (delta = 19 +/- 25 V LEV; P < 0.03). CONCLUSIONS: Shock delivery during cardiac compression improves defibrillation efficacy. Additionally, cardiac compression decreases both DFT and ULV, which supports the ULV hypothesis of defibrillation. Finally, maintaining the heart's geometric and volumetric state during ULV testing in paced rhythm and DFT testing in ventricular fibrillation moves the ULV higher than the DFT-the position predicted by the ULV hypothesis for defibrillation.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Cardiovasc Electrophysiol

DOI

ISSN

1045-3873

Publication Date

May 1995

Volume

6

Issue

5

Start / End Page

368 / 378

Location

United States

Related Subject Headings

  • Ventricular Function
  • Swine
  • In Vitro Techniques
  • Heart
  • Electroshock
  • Electrodes
  • Electric Countershock
  • Cardiovascular System & Hematology
  • Cardiac Volume
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Idriss, S. F., Anstadt, M. P., Anstadt, G. L., & Ideker, R. E. (1995). The effect of cardiac compression on defibrillation efficacy and the upper limit of vulnerability. J Cardiovasc Electrophysiol, 6(5), 368–378. https://doi.org/10.1111/j.1540-8167.1995.tb00410.x
Idriss, S. F., M. P. Anstadt, G. L. Anstadt, and R. E. Ideker. “The effect of cardiac compression on defibrillation efficacy and the upper limit of vulnerability.J Cardiovasc Electrophysiol 6, no. 5 (May 1995): 368–78. https://doi.org/10.1111/j.1540-8167.1995.tb00410.x.
Idriss SF, Anstadt MP, Anstadt GL, Ideker RE. The effect of cardiac compression on defibrillation efficacy and the upper limit of vulnerability. J Cardiovasc Electrophysiol. 1995 May;6(5):368–78.
Idriss, S. F., et al. “The effect of cardiac compression on defibrillation efficacy and the upper limit of vulnerability.J Cardiovasc Electrophysiol, vol. 6, no. 5, May 1995, pp. 368–78. Pubmed, doi:10.1111/j.1540-8167.1995.tb00410.x.
Idriss SF, Anstadt MP, Anstadt GL, Ideker RE. The effect of cardiac compression on defibrillation efficacy and the upper limit of vulnerability. J Cardiovasc Electrophysiol. 1995 May;6(5):368–378.
Journal cover image

Published In

J Cardiovasc Electrophysiol

DOI

ISSN

1045-3873

Publication Date

May 1995

Volume

6

Issue

5

Start / End Page

368 / 378

Location

United States

Related Subject Headings

  • Ventricular Function
  • Swine
  • In Vitro Techniques
  • Heart
  • Electroshock
  • Electrodes
  • Electric Countershock
  • Cardiovascular System & Hematology
  • Cardiac Volume
  • Animals