Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel

Bacteremia, central catheters, and neonates: when to pull the line.

Publication ,  Journal Article
Benjamin, DK; Miller, W; Garges, H; McKinney, RE; Cotton, M; Fisher, RG; Alexander, KA
Published in: Pediatrics
June 2001

OBJECTIVES: Physicians who treat neonates who become bacteremic while dependent on central venous catheters face a serious and common dilemma. We sought 1) to evaluate the relationship between central venous catheter removal and outcome in bacteremic neonates, 2) to determine species of bacteria that are associated with an increased risk of infectious complications if the central catheter is not removed promptly, and 3) to provide evidence-based recommendations for central catheter management. METHOD: A retrospective cohort study of all neonates who had central venous access and developed bacteremia between July 1, 1995, and July 31, 1999, was conducted in the Duke University neonatal intensive care unit. RESULTS: The outcome for patients in whom the central catheter was not removed within 24 hours of organism identification was significantly worse (odds ratio = 9.8) than it was for those whose catheters were removed promptly. For patients who were infected with Staphylococcus aureus or with nonenteric Gram-negative rods, delayed removal of the central catheter was associated with complicated bacteremia. Catheter sterilization was attempted in 27 neonates who were infected with enteric Gram-negative rods; only 10 of these infants retained their catheters without infection-related complications. Infants who had 4 consecutive blood cultures that were positive for coagulase-negative staphylococcus (CoNS) were at significantly increased risk for end-organ damage and death, compared with infants who had 3 or fewer positive blood culture for CoNS (odds ratio = 29.58). CONCLUSIONS: Bacteremic infants experienced fewer infection-related complications when the central catheter was removed promptly. One positive blood culture for S aureus or a Gram-negative rod warrants central line removal in a neonate. Clinicians who are faced with a neonate who has 1 positive culture for CoNS may attempt medical management without central catheter removal, but documentation of subsequent negative blood cultures is crucial. Once a neonate has 3 positive blood cultures for CoNS, the central catheter should be removed.central line, neonate, bacteremia, bacteria, umbilical catheter, Broviac, percutaneous.

Duke Scholars

Published In

Pediatrics

DOI

EISSN

1098-4275

Publication Date

June 2001

Volume

107

Issue

6

Start / End Page

1272 / 1276

Location

United States

Related Subject Headings

  • Time Factors
  • Staphylococcus aureus
  • Practice Guidelines as Topic
  • Pediatrics
  • Neonatology
  • Intensive Care, Neonatal
  • Intensive Care Units, Neonatal
  • Infant, Newborn
  • Humans
  • Equipment Contamination
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Benjamin, D. K., Miller, W., Garges, H., McKinney, R. E., Cotton, M., Fisher, R. G., & Alexander, K. A. (2001). Bacteremia, central catheters, and neonates: when to pull the line. Pediatrics, 107(6), 1272–1276. https://doi.org/10.1542/peds.107.6.1272
Benjamin, D. K., W. Miller, H. Garges, R. E. McKinney, M. Cotton, R. G. Fisher, and K. A. Alexander. “Bacteremia, central catheters, and neonates: when to pull the line.Pediatrics 107, no. 6 (June 2001): 1272–76. https://doi.org/10.1542/peds.107.6.1272.
Benjamin DK, Miller W, Garges H, McKinney RE, Cotton M, Fisher RG, et al. Bacteremia, central catheters, and neonates: when to pull the line. Pediatrics. 2001 Jun;107(6):1272–6.
Benjamin, D. K., et al. “Bacteremia, central catheters, and neonates: when to pull the line.Pediatrics, vol. 107, no. 6, June 2001, pp. 1272–76. Pubmed, doi:10.1542/peds.107.6.1272.
Benjamin DK, Miller W, Garges H, McKinney RE, Cotton M, Fisher RG, Alexander KA. Bacteremia, central catheters, and neonates: when to pull the line. Pediatrics. 2001 Jun;107(6):1272–1276.

Published In

Pediatrics

DOI

EISSN

1098-4275

Publication Date

June 2001

Volume

107

Issue

6

Start / End Page

1272 / 1276

Location

United States

Related Subject Headings

  • Time Factors
  • Staphylococcus aureus
  • Practice Guidelines as Topic
  • Pediatrics
  • Neonatology
  • Intensive Care, Neonatal
  • Intensive Care Units, Neonatal
  • Infant, Newborn
  • Humans
  • Equipment Contamination