Skip to main content
Journal cover image

Three-dimensional tomography using a cubic-phase plate extended depth-of-field system

Publication ,  Journal Article
Marks, DL; Stack, RA; Brady, DJ; Van Der Gracht, J
Published in: Optics Letters
February 15, 1999

We use cubic-phase plate imaging to demonstrate an order-of-magnitude improvement in the transverse resolution of three-dimensional objects reconstructed by extended depth-of-field tomography. Our algorithm compensates for the range shear of the cubic-phase approach and uses camera rotation to center the reconstructed volume on a target object point. © 1999 Optical Society of America.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Optics Letters

DOI

ISSN

0146-9592

Publication Date

February 15, 1999

Volume

24

Issue

4

Start / End Page

253 / 255

Related Subject Headings

  • Optics
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
  • 0906 Electrical and Electronic Engineering
  • 0206 Quantum Physics
  • 0205 Optical Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Marks, D. L., Stack, R. A., Brady, D. J., & Van Der Gracht, J. (1999). Three-dimensional tomography using a cubic-phase plate extended depth-of-field system. Optics Letters, 24(4), 253–255. https://doi.org/10.1364/OL.24.000253
Marks, D. L., R. A. Stack, D. J. Brady, and J. Van Der Gracht. “Three-dimensional tomography using a cubic-phase plate extended depth-of-field system.” Optics Letters 24, no. 4 (February 15, 1999): 253–55. https://doi.org/10.1364/OL.24.000253.
Marks DL, Stack RA, Brady DJ, Van Der Gracht J. Three-dimensional tomography using a cubic-phase plate extended depth-of-field system. Optics Letters. 1999 Feb 15;24(4):253–5.
Marks, D. L., et al. “Three-dimensional tomography using a cubic-phase plate extended depth-of-field system.” Optics Letters, vol. 24, no. 4, Feb. 1999, pp. 253–55. Scopus, doi:10.1364/OL.24.000253.
Marks DL, Stack RA, Brady DJ, Van Der Gracht J. Three-dimensional tomography using a cubic-phase plate extended depth-of-field system. Optics Letters. 1999 Feb 15;24(4):253–255.
Journal cover image

Published In

Optics Letters

DOI

ISSN

0146-9592

Publication Date

February 15, 1999

Volume

24

Issue

4

Start / End Page

253 / 255

Related Subject Headings

  • Optics
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
  • 0906 Electrical and Electronic Engineering
  • 0206 Quantum Physics
  • 0205 Optical Physics