FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation.
Publication
, Journal Article
Morsy, AA; Von Ramm, OT
Published in: IEEE transactions on ultrasonics, ferroelectrics, and frequency control
January 1999
We report a new method for tracking tissue motion and blood flow in three dimensions (3-D) using successive volumetric ultrasound scans. The method is based on combining the concepts of feature tracking and 3-D correlation search to achieve a compromise between accuracy and computational efficiency. This paper introduces the new method and the experimental setup used for its evaluation in a tissue-mimicking material. Results are presented demonstrating that the new method has both satisfactory tracking performance and the potential for practical real-time implementation.
Duke Scholars
Published In
IEEE transactions on ultrasonics, ferroelectrics, and frequency control
DOI
EISSN
1525-8955
ISSN
0885-3010
Publication Date
January 1999
Volume
46
Issue
3
Start / End Page
728 / 736
Related Subject Headings
- Acoustics
- 51 Physical sciences
- 40 Engineering
- 09 Engineering
- 02 Physical Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Morsy, A. A., & Von Ramm, O. T. (1999). FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 46(3), 728–736. https://doi.org/10.1109/58.764859
Morsy, A. A., and O. T. Von Ramm. “FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 46, no. 3 (January 1999): 728–36. https://doi.org/10.1109/58.764859.
Morsy AA, Von Ramm OT. FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation. IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 1999 Jan;46(3):728–36.
Morsy, A. A., and O. T. Von Ramm. “FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 46, no. 3, Jan. 1999, pp. 728–36. Epmc, doi:10.1109/58.764859.
Morsy AA, Von Ramm OT. FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation. IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 1999 Jan;46(3):728–736.
Published In
IEEE transactions on ultrasonics, ferroelectrics, and frequency control
DOI
EISSN
1525-8955
ISSN
0885-3010
Publication Date
January 1999
Volume
46
Issue
3
Start / End Page
728 / 736
Related Subject Headings
- Acoustics
- 51 Physical sciences
- 40 Engineering
- 09 Engineering
- 02 Physical Sciences