Skip to main content

Crossed-beam two-photon readout system for three-dimensional radiation dosimeters

Publication ,  Journal Article
Song, JM; Cullum, BM; Mobley, J; Bogard, JS; Moscovitch, M; Phillips, GW; Vo-Dinh, T
Published in: Review of Scientific Instruments
December 1, 2002

A two-photon readout system, that allowed for the readout of information on ionizing radiation from the three dimensional (3D) optical random access memory (ORAM) materials without polymer fracturing, was investigated. A Q-switched, frequency-doubled Nd:YAG laser was used as the two-photon excitation source. An optical attenuator was employed to adjust the intensity of the 1064 nm laser beam. It was found that the two-photon excited fluorescence of anthracene-doped 3D ORAM materials could be obtained without polymer fracturing.

Duke Scholars

Published In

Review of Scientific Instruments

DOI

ISSN

0034-6748

Publication Date

December 1, 2002

Volume

73

Issue

12

Start / End Page

4214 / 4217

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Song, J. M., Cullum, B. M., Mobley, J., Bogard, J. S., Moscovitch, M., Phillips, G. W., & Vo-Dinh, T. (2002). Crossed-beam two-photon readout system for three-dimensional radiation dosimeters. Review of Scientific Instruments, 73(12), 4214–4217. https://doi.org/10.1063/1.1518789
Song, J. M., B. M. Cullum, J. Mobley, J. S. Bogard, M. Moscovitch, G. W. Phillips, and T. Vo-Dinh. “Crossed-beam two-photon readout system for three-dimensional radiation dosimeters.” Review of Scientific Instruments 73, no. 12 (December 1, 2002): 4214–17. https://doi.org/10.1063/1.1518789.
Song JM, Cullum BM, Mobley J, Bogard JS, Moscovitch M, Phillips GW, et al. Crossed-beam two-photon readout system for three-dimensional radiation dosimeters. Review of Scientific Instruments. 2002 Dec 1;73(12):4214–7.
Song, J. M., et al. “Crossed-beam two-photon readout system for three-dimensional radiation dosimeters.” Review of Scientific Instruments, vol. 73, no. 12, Dec. 2002, pp. 4214–17. Scopus, doi:10.1063/1.1518789.
Song JM, Cullum BM, Mobley J, Bogard JS, Moscovitch M, Phillips GW, Vo-Dinh T. Crossed-beam two-photon readout system for three-dimensional radiation dosimeters. Review of Scientific Instruments. 2002 Dec 1;73(12):4214–4217.

Published In

Review of Scientific Instruments

DOI

ISSN

0034-6748

Publication Date

December 1, 2002

Volume

73

Issue

12

Start / End Page

4214 / 4217

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences