Comparison of multichannel SIT image vidicon and photomultiplier sequential linear scanning systems for the measurement of steady-state and transient fluorescence of molecules in solution
Publication
, Journal Article
Cooney, RP; Vo Dinh, T; Walden, G; Winefordner, JD
Published in: Anal. Chem. (USA)
1977
The feasibility of using the SIT image vidicon as a potential detector for liquid chromatography is demonstrated. Limits of detection range from ~2×10-2 ng for anthracene to ~6×10-1 ng for riboflavin. A direct experimental comparison is made of a silicon intensified target vidicon multichannel (SIT-MC) and a photomultiplier sequential linear scanning (PM-SLS) system for the detection of steady-state fluorescence from molecules in solution. The PM system is slightly better than the SIT for measuring steady-state fluorescence; on the other hand, the multichannel advantage of the SIT would appear to make it the better system for measuring transient fluorescence signals
Duke Scholars
Published In
Anal. Chem. (USA)
Publication Date
1977
Volume
49
Issue
7
Start / End Page
939 / 943
Related Subject Headings
- Analytical Chemistry
- 4004 Chemical engineering
- 3401 Analytical chemistry
- 3205 Medical biochemistry and metabolomics
- 0399 Other Chemical Sciences
- 0301 Analytical Chemistry
Citation
APA
Chicago
ICMJE
MLA
NLM
Cooney, R. P., Vo Dinh, T., Walden, G., & Winefordner, J. D. (1977). Comparison of multichannel SIT image vidicon and photomultiplier sequential linear scanning systems for the measurement of steady-state and transient fluorescence of molecules in solution. Anal. Chem. (USA), 49(7), 939–943.
Cooney, R. P., T. Vo Dinh, G. Walden, and J. D. Winefordner. “Comparison of multichannel SIT image vidicon and photomultiplier sequential linear scanning systems for the measurement of steady-state and transient fluorescence of molecules in solution.” Anal. Chem. (USA) 49, no. 7 (1977): 939–43.
Cooney RP, Vo Dinh T, Walden G, Winefordner JD. Comparison of multichannel SIT image vidicon and photomultiplier sequential linear scanning systems for the measurement of steady-state and transient fluorescence of molecules in solution. Anal Chem (USA). 1977;49(7):939–43.
Cooney, R. P., et al. “Comparison of multichannel SIT image vidicon and photomultiplier sequential linear scanning systems for the measurement of steady-state and transient fluorescence of molecules in solution.” Anal. Chem. (USA), vol. 49, no. 7, 1977, pp. 939–43.
Cooney RP, Vo Dinh T, Walden G, Winefordner JD. Comparison of multichannel SIT image vidicon and photomultiplier sequential linear scanning systems for the measurement of steady-state and transient fluorescence of molecules in solution. Anal Chem (USA). 1977;49(7):939–943.
Published In
Anal. Chem. (USA)
Publication Date
1977
Volume
49
Issue
7
Start / End Page
939 / 943
Related Subject Headings
- Analytical Chemistry
- 4004 Chemical engineering
- 3401 Analytical chemistry
- 3205 Medical biochemistry and metabolomics
- 0399 Other Chemical Sciences
- 0301 Analytical Chemistry