Optical monitor for microbial metabolism for hazardous waste application
Publication
, Journal Article
Ryan-Baker, M; Vo-Dinh, T; Griffin, GD; Miller, GH; Alarie, JP; Burlage, RS; Palumbo, AV; White, DC; Herbes, S
Published in: Proceedings of SPIE - The International Society for Optical Engineering
January 1, 1992
A remote detection system for in-situ monitoring of the bioluminescence produced by a microbial `reporter' strain grown in rotary film bioreactors has been developed. Two systems were developed: one using a low-temperature photomultiplier, and one using an avalanche photodiode. The photodiode system was preferred for its sensitivity and portability. Testing was performed on a recombinant constitutive light producing strain. The results indicate that the optical monitor is sensitive enough for direct microbial detection for hazardous waste application.
Duke Scholars
Published In
Proceedings of SPIE - The International Society for Optical Engineering
ISSN
0277-786X
Publication Date
January 1, 1992
Volume
1637
Start / End Page
196 / 207
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Ryan-Baker, M., Vo-Dinh, T., Griffin, G. D., Miller, G. H., Alarie, J. P., Burlage, R. S., … Herbes, S. (1992). Optical monitor for microbial metabolism for hazardous waste application. Proceedings of SPIE - The International Society for Optical Engineering, 1637, 196–207.
Ryan-Baker, M., T. Vo-Dinh, G. D. Griffin, G. H. Miller, J. P. Alarie, R. S. Burlage, A. V. Palumbo, D. C. White, and S. Herbes. “Optical monitor for microbial metabolism for hazardous waste application.” Proceedings of SPIE - The International Society for Optical Engineering 1637 (January 1, 1992): 196–207.
Ryan-Baker M, Vo-Dinh T, Griffin GD, Miller GH, Alarie JP, Burlage RS, et al. Optical monitor for microbial metabolism for hazardous waste application. Proceedings of SPIE - The International Society for Optical Engineering. 1992 Jan 1;1637:196–207.
Ryan-Baker, M., et al. “Optical monitor for microbial metabolism for hazardous waste application.” Proceedings of SPIE - The International Society for Optical Engineering, vol. 1637, Jan. 1992, pp. 196–207.
Ryan-Baker M, Vo-Dinh T, Griffin GD, Miller GH, Alarie JP, Burlage RS, Palumbo AV, White DC, Herbes S. Optical monitor for microbial metabolism for hazardous waste application. Proceedings of SPIE - The International Society for Optical Engineering. 1992 Jan 1;1637:196–207.
Published In
Proceedings of SPIE - The International Society for Optical Engineering
ISSN
0277-786X
Publication Date
January 1, 1992
Volume
1637
Start / End Page
196 / 207
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering