Skip to main content

Adaptive processing algorithms for intravenous digital subtraction coronary angiography

Publication ,  Journal Article
Lee, CSR; Peppier, WW; Van Lysel, MS; Cusma, JT; Folts, JD; Zarnstorff, WC; Mistretta, CA; Dobbins, JT; Hasegawa, BH; Naimuddin, S; Molloi, S ...
Published in: Proceedings of SPIE - The International Society for Optical Engineering
June 11, 1985

Digital Subtraction Angiography (DSA) is commonly used in conjunction with intravenous contrast injection for detection of atherosclerotic disease in arteries outside of the heart. Images of coronary arteries obtained with intravenous DSA have been limited in quality by several important factors. Among these is the confusing background provided by superposed pulmonary veins. Because these opacity just before the coronary arteries, conventional remasking results in substantial loss in coronary artery contrast. This paper presents preliminary work on a processing scheme in which the degree of correlation between the contrast pass curves in individual pixels and a reference region can be used to adaptively suppress pulmonary structures. © 1985 SPIE.

Duke Scholars

Published In

Proceedings of SPIE - The International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

June 11, 1985

Volume

535

Start / End Page

369 / 377
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lee, C. S. R., Peppier, W. W., Van Lysel, M. S., Cusma, J. T., Folts, J. D., Zarnstorff, W. C., … Lancaster, J. C. (1985). Adaptive processing algorithms for intravenous digital subtraction coronary angiography. Proceedings of SPIE - The International Society for Optical Engineering, 535, 369–377. https://doi.org/10.1117/12.947292
Lee, C. S. R., W. W. Peppier, M. S. Van Lysel, J. T. Cusma, J. D. Folts, W. C. Zarnstorff, C. A. Mistretta, et al. “Adaptive processing algorithms for intravenous digital subtraction coronary angiography.” Proceedings of SPIE - The International Society for Optical Engineering 535 (June 11, 1985): 369–77. https://doi.org/10.1117/12.947292.
Lee CSR, Peppier WW, Van Lysel MS, Cusma JT, Folts JD, Zarnstorff WC, et al. Adaptive processing algorithms for intravenous digital subtraction coronary angiography. Proceedings of SPIE - The International Society for Optical Engineering. 1985 Jun 11;535:369–77.
Lee, C. S. R., et al. “Adaptive processing algorithms for intravenous digital subtraction coronary angiography.” Proceedings of SPIE - The International Society for Optical Engineering, vol. 535, June 1985, pp. 369–77. Scopus, doi:10.1117/12.947292.
Lee CSR, Peppier WW, Van Lysel MS, Cusma JT, Folts JD, Zarnstorff WC, Mistretta CA, Dobbins JT, Hasegawa BH, Naimuddin S, Molloi S, Hangiandreou N, Lancaster JC. Adaptive processing algorithms for intravenous digital subtraction coronary angiography. Proceedings of SPIE - The International Society for Optical Engineering. 1985 Jun 11;535:369–377.

Published In

Proceedings of SPIE - The International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

June 11, 1985

Volume

535

Start / End Page

369 / 377