Skip to main content

Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses.

Publication ,  Journal Article
Cain, CP; Toth, CA; Thomas, RJ; Noojin, GD; Carothers, V; Stolarski, DJ; Rockwell, BA
Published in: J Biomed Opt
July 2000

Single 130 fs laser pulses in the near-IR (800 nm) were used to create ophthalmoscopically viewed minimum visible lesions (MVLs) within the macular and paramacular regions in rhesus monkey eyes. MVL thresholds at 1 and 24 h are reported as the 50% probability for damage (ED50) together with their fiducial limits at the 95% confidence level. These measured thresholds are compared with previously reported thresholds for near-IR and visible wavelengths for both macular and paramacular areas. Threshold doses were lower at the 24 h reading than at the 1 h reading for both retinal regions and the ED50s for the macula were slightly lower than for the paramacula. We measured the 24 h MVL ED50 thresholds to be 0.35 and 0.55 microJ for the macular and paramacular areas, respectively. The combined data for both areas yielded a threshold of 0.45 microJ.

Duke Scholars

Published In

J Biomed Opt

DOI

ISSN

1083-3668

Publication Date

July 2000

Volume

5

Issue

3

Start / End Page

315 / 320

Location

United States

Related Subject Headings

  • Sensory Thresholds
  • Retina
  • Reproducibility of Results
  • Optics
  • Ophthalmoscopy
  • Macula Lutea
  • Macaca mulatta
  • Lasers
  • Eye Injuries
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cain, C. P., Toth, C. A., Thomas, R. J., Noojin, G. D., Carothers, V., Stolarski, D. J., & Rockwell, B. A. (2000). Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses. J Biomed Opt, 5(3), 315–320. https://doi.org/10.1117/1.430002
Cain, C. P., C. A. Toth, R. J. Thomas, G. D. Noojin, V. Carothers, D. J. Stolarski, and B. A. Rockwell. “Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses.J Biomed Opt 5, no. 3 (July 2000): 315–20. https://doi.org/10.1117/1.430002.
Cain CP, Toth CA, Thomas RJ, Noojin GD, Carothers V, Stolarski DJ, et al. Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses. J Biomed Opt. 2000 Jul;5(3):315–20.
Cain, C. P., et al. “Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses.J Biomed Opt, vol. 5, no. 3, July 2000, pp. 315–20. Pubmed, doi:10.1117/1.430002.
Cain CP, Toth CA, Thomas RJ, Noojin GD, Carothers V, Stolarski DJ, Rockwell BA. Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses. J Biomed Opt. 2000 Jul;5(3):315–320.

Published In

J Biomed Opt

DOI

ISSN

1083-3668

Publication Date

July 2000

Volume

5

Issue

3

Start / End Page

315 / 320

Location

United States

Related Subject Headings

  • Sensory Thresholds
  • Retina
  • Reproducibility of Results
  • Optics
  • Ophthalmoscopy
  • Macula Lutea
  • Macaca mulatta
  • Lasers
  • Eye Injuries
  • Animals