Skip to main content

Radiation dosimetry using polymer gels: methods and applications.

Publication ,  Journal Article
McJury, M; Oldham, M; Cosgrove, VP; Murphy, PS; Doran, S; Leach, MO; Webb, S
Published in: Br J Radiol
September 2000

New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and application to radiotherapy verification. The dosimeters consist of a gel matrix within which is suspended a solution of acrylic molecules. These molecules polymerize upon exposure to radiation, with the degree of polymerization being proportional to absorbed dose. The polymer distribution can be measured in two or three dimensions using MRI or optical tomography and, after calibration, the images can be converted into radiation dose distributions. Manufacture of the gel is reported to be reproducible, and measured dose in the range 0-10 Gy is accurate to within 3-5%. In-plane image resolution of 1 mm x 1 mm, with image slice thicknesses of between 2-5 mm, is typically achievable using clinical 1.5 T MR scanners and standard T2 weighted imaging sequences. The gels have been used to verify a number of conventional and novel radiotherapy modalities, including brachytherapy, intensity modulated radiotherapy and stereotactic radiosurgery. All the studies have confirmed the value and versatility of the dosimetry technique.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Br J Radiol

DOI

ISSN

0007-1285

Publication Date

September 2000

Volume

73

Issue

873

Start / End Page

919 / 929

Location

England

Related Subject Headings

  • Reproducibility of Results
  • Radiometry
  • Polymers
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Gels
  • Gelatin
  • Equipment Failure
  • Calibration
  • Acrylamide
 

Citation

APA
Chicago
ICMJE
MLA
NLM
McJury, M., Oldham, M., Cosgrove, V. P., Murphy, P. S., Doran, S., Leach, M. O., & Webb, S. (2000). Radiation dosimetry using polymer gels: methods and applications. Br J Radiol, 73(873), 919–929. https://doi.org/10.1259/bjr.73.873.11064643
McJury, M., M. Oldham, V. P. Cosgrove, P. S. Murphy, S. Doran, M. O. Leach, and S. Webb. “Radiation dosimetry using polymer gels: methods and applications.Br J Radiol 73, no. 873 (September 2000): 919–29. https://doi.org/10.1259/bjr.73.873.11064643.
McJury M, Oldham M, Cosgrove VP, Murphy PS, Doran S, Leach MO, et al. Radiation dosimetry using polymer gels: methods and applications. Br J Radiol. 2000 Sep;73(873):919–29.
McJury, M., et al. “Radiation dosimetry using polymer gels: methods and applications.Br J Radiol, vol. 73, no. 873, Sept. 2000, pp. 919–29. Pubmed, doi:10.1259/bjr.73.873.11064643.
McJury M, Oldham M, Cosgrove VP, Murphy PS, Doran S, Leach MO, Webb S. Radiation dosimetry using polymer gels: methods and applications. Br J Radiol. 2000 Sep;73(873):919–929.

Published In

Br J Radiol

DOI

ISSN

0007-1285

Publication Date

September 2000

Volume

73

Issue

873

Start / End Page

919 / 929

Location

England

Related Subject Headings

  • Reproducibility of Results
  • Radiometry
  • Polymers
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Gels
  • Gelatin
  • Equipment Failure
  • Calibration
  • Acrylamide