Skip to main content

A scanning electron microscope study of porcine corneal endothelium stored in chondroitin sulphate.

Publication ,  Journal Article
Ellis, MF; McGhee, CN; Lee, WR
Published in: Cornea
March 1992

The porcine cornea was used as a model for the study of the effects of corneal storage in 2.5% chondroitin sulphate at 3, 5, 8, and 10 days. The corneal endothelium was studied by scanning electron microscopy and image analysis was used to measure cell area, density, and the percentage of cell disruption and loss. Corneal endothelial cells from freshly slaughtered 5- to 6-month-old pigs had a mean posterior surface area of 134 +/- 30 microns2 and a density of 6,300 +/- 640 cells/mm2. In storage conditions, there was a decrease in cell area to 102 +/- 18 microns2 at 5 days and 88 +/- 23 microns2 at 10 days of storage, with a cell density of 7,110 cells/mm2 at 5 days and 6,500 cells/mm2 at 10 days. There was a disruption rate of 12% at 5 days and 26% at 10 days of storage. The effect on the endothelium after suspension in storage medium was compared with laying the corneas endothelium uppermost. An increased disruption rate was found in the suspended corneas. The effect of the time interval between enucleation and preparation on percentage cellular disruption was linear.

Duke Scholars

Published In

Cornea

DOI

ISSN

0277-3740

Publication Date

March 1992

Volume

11

Issue

2

Start / End Page

127 / 132

Location

United States

Related Subject Headings

  • Swine
  • Organ Preservation
  • Ophthalmology & Optometry
  • Microscopy, Electron, Scanning
  • Image Processing, Computer-Assisted
  • Endothelium, Corneal
  • Culture Media
  • Chondroitin Sulfates
  • Cell Count
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ellis, M. F., McGhee, C. N., & Lee, W. R. (1992). A scanning electron microscope study of porcine corneal endothelium stored in chondroitin sulphate. Cornea, 11(2), 127–132. https://doi.org/10.1097/00003226-199203000-00006
Ellis, M. F., C. N. McGhee, and W. R. Lee. “A scanning electron microscope study of porcine corneal endothelium stored in chondroitin sulphate.Cornea 11, no. 2 (March 1992): 127–32. https://doi.org/10.1097/00003226-199203000-00006.
Ellis, M. F., et al. “A scanning electron microscope study of porcine corneal endothelium stored in chondroitin sulphate.Cornea, vol. 11, no. 2, Mar. 1992, pp. 127–32. Pubmed, doi:10.1097/00003226-199203000-00006.

Published In

Cornea

DOI

ISSN

0277-3740

Publication Date

March 1992

Volume

11

Issue

2

Start / End Page

127 / 132

Location

United States

Related Subject Headings

  • Swine
  • Organ Preservation
  • Ophthalmology & Optometry
  • Microscopy, Electron, Scanning
  • Image Processing, Computer-Assisted
  • Endothelium, Corneal
  • Culture Media
  • Chondroitin Sulfates
  • Cell Count
  • Animals