Skip to main content

Failure of low molecular weight dextran to prevent clotting during continuous renal replacement therapy.

Publication ,  Journal Article
Palevsky, PM; Burr, R; Moreland, L; Tokiwa, Y; Greenberg, A
Published in: ASAIO J
1995

Clotting of the extracorporeal circuit during continuous renal replacement therapy results in decreased ultrafiltration rates, impaired solute clearance and, ultimately, occlusion of the extracorporeal circuit. The authors conducted an open-label randomized controlled trial to determine whether low molecular weight dextran could prevent hemofilter clotting in patients undergoing continuous venovenous hemodialysis. Eleven patients were randomized to receive a continuous infusion of 10% low molecular weight dextran at 25 mL/hr; 8 patients served as control subjects. No differences in the frequency of hemofilter clotting or hemofilter lifespan were detected. The authors concluded that continuous infusion of low dose low molecular weight dextran is not effective in preventing clotting during continuous renal replacement therapy.

Duke Scholars

Published In

ASAIO J

ISSN

1058-2916

Publication Date

1995

Volume

41

Issue

4

Start / End Page

847 / 849

Location

United States

Related Subject Headings

  • Renal Dialysis
  • Postoperative Complications
  • Platelet Count
  • Molecular Weight
  • Middle Aged
  • Male
  • Infusions, Intravenous
  • Humans
  • Hemofiltration
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Palevsky, P. M., Burr, R., Moreland, L., Tokiwa, Y., & Greenberg, A. (1995). Failure of low molecular weight dextran to prevent clotting during continuous renal replacement therapy. ASAIO J, 41(4), 847–849.
Palevsky, P. M., R. Burr, L. Moreland, Y. Tokiwa, and A. Greenberg. “Failure of low molecular weight dextran to prevent clotting during continuous renal replacement therapy.ASAIO J 41, no. 4 (1995): 847–49.
Palevsky PM, Burr R, Moreland L, Tokiwa Y, Greenberg A. Failure of low molecular weight dextran to prevent clotting during continuous renal replacement therapy. ASAIO J. 1995;41(4):847–9.
Palevsky, P. M., et al. “Failure of low molecular weight dextran to prevent clotting during continuous renal replacement therapy.ASAIO J, vol. 41, no. 4, 1995, pp. 847–49.
Palevsky PM, Burr R, Moreland L, Tokiwa Y, Greenberg A. Failure of low molecular weight dextran to prevent clotting during continuous renal replacement therapy. ASAIO J. 1995;41(4):847–849.

Published In

ASAIO J

ISSN

1058-2916

Publication Date

1995

Volume

41

Issue

4

Start / End Page

847 / 849

Location

United States

Related Subject Headings

  • Renal Dialysis
  • Postoperative Complications
  • Platelet Count
  • Molecular Weight
  • Middle Aged
  • Male
  • Infusions, Intravenous
  • Humans
  • Hemofiltration
  • Female