The serial changes in aortic regurgitation (AR) after balloon aortic valvuloplasty have not been quantitatively evaluated. This study assessed the degree of AR by quantitative and qualitative techniques before and immediately after aortic valvuloplasty. Digital subtraction aortography was performed before and after valvuloplasty in 50 patients. The ratio of left ventricular to aortic contrast density during aortography was analyzed by videodensitometric techniques. A time-density curve was obtained by placing a 30 X 30 pixel region of interest over the aortogram and the left ventricular cavity. The ratio of left ventricular to aortic density at peak aortic density defined the videodensitometric ratio. Independent visual interpretation was also assessed and compared to videodensitometric methods. Quantitatively, no significant change in AR could be demonstrated in the mean videodensitometric ratio before or after balloon aortic valvuloplasty (0.33 +/- 0.21 vs 0.37 +/- 0.25, p = 0.07). Ten (20%) of the patients had a greater than or equal to 0.10 increase, and 4 (8%) patients a greater than or equal to 0.10 decrease in the AR ratio. Thus, serial quantitative and qualitative determinations of AR after balloon aortic valvuloplasty confirm that significant increases or decreases in AR severity are unusual after the procedure.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Am J Cardiol

DOI

ISSN

0002-9149

Publication Date

March 1, 1989

Volume

63

Issue

9

Start / End Page

585 / 588

Location

United States

Related Subject Headings

  • Subtraction Technique
  • Radiographic Image Enhancement
  • Middle Aged
  • Humans
  • Catheterization
  • Cardiovascular System & Hematology
  • Aortography
  • Aortic Valve Insufficiency
  • Aged, 80 and over
  • Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Davidson, C. J., Kisslo, K., Burgess, R., & Bashore, T. M. (1989). Quantification of aortic regurgitation after balloon aortic valvuloplasty using videodensitometric analysis of digital subtraction aortography. Am J Cardiol, 63(9), 585–588. https://doi.org/10.1016/0002-9149(89)90903-x
Davidson, C. J., K. Kisslo, R. Burgess, and T. M. Bashore. “Quantification of aortic regurgitation after balloon aortic valvuloplasty using videodensitometric analysis of digital subtraction aortography.Am J Cardiol 63, no. 9 (March 1, 1989): 585–88. https://doi.org/10.1016/0002-9149(89)90903-x.
Davidson, C. J., et al. “Quantification of aortic regurgitation after balloon aortic valvuloplasty using videodensitometric analysis of digital subtraction aortography.Am J Cardiol, vol. 63, no. 9, Mar. 1989, pp. 585–88. Pubmed, doi:10.1016/0002-9149(89)90903-x.
Journal cover image

Published In

Am J Cardiol

DOI

ISSN

0002-9149

Publication Date

March 1, 1989

Volume

63

Issue

9

Start / End Page

585 / 588

Location

United States

Related Subject Headings

  • Subtraction Technique
  • Radiographic Image Enhancement
  • Middle Aged
  • Humans
  • Catheterization
  • Cardiovascular System & Hematology
  • Aortography
  • Aortic Valve Insufficiency
  • Aged, 80 and over
  • Aged