Skip to main content
Journal cover image

Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography.

Publication ,  Journal Article
Debatin, JF; Nadel, SN; Paolini, JF; Sostman, HD; Coleman, RE; Evans, AJ; Beam, C; Spritzer, CE; Bashore, TM
Published in: J Magn Reson Imaging
1992

The accuracy and reproducibility of cardiac ejection fraction (EF) measurements based on cine magnetic resonance (MR) imaging, radionuclide multigated acquisition (MUGA) blood pool imaging, and angiographic ventriculography were evaluated by comparing them with a volumetrically determined standard. A biventricular, compliant, fluid-filled heart phantom was developed to mimic normal cardiac anatomy and physiology. Ventricular EFs were measured with cine MR imaging by summation of nine contiguous 10-mm-thick sections in short and long axis, with single-plane ventriculography, and with MUGA. Three measurements were performed with each modality for each of three EFs. Ventriculography was least accurate, with average relative errors ranging from 7.9% for the largest EF to 60.1% for the smallest. Cine MR was most accurate, with average relative errors ranging from 4.4% to 8.5%. MUGA EF measurements showed good correlation, with average relative errors ranging from 7.1% to 22.4%. Comparison of the error variances for the three modalities with the F test revealed that MR and MUGA EF measurements were significantly more accurate than those based on ventriculography (P less than .01). No significant difference was demonstrated between the accuracy of short- and long-axis cine MR acquisitions.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

1992

Volume

2

Issue

2

Start / End Page

135 / 142

Location

United States

Related Subject Headings

  • Ventriculography, First-Pass
  • Stroke Volume
  • Nuclear Medicine & Medical Imaging
  • Motion Pictures
  • Models, Structural
  • Magnetic Resonance Imaging
  • In Vitro Techniques
  • Humans
  • Gated Blood-Pool Imaging
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Debatin, J. F., Nadel, S. N., Paolini, J. F., Sostman, H. D., Coleman, R. E., Evans, A. J., … Bashore, T. M. (1992). Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography. J Magn Reson Imaging, 2(2), 135–142. https://doi.org/10.1002/jmri.1880020205
Debatin, J. F., S. N. Nadel, J. F. Paolini, H. D. Sostman, R. E. Coleman, A. J. Evans, C. Beam, C. E. Spritzer, and T. M. Bashore. “Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography.J Magn Reson Imaging 2, no. 2 (1992): 135–42. https://doi.org/10.1002/jmri.1880020205.
Debatin JF, Nadel SN, Paolini JF, Sostman HD, Coleman RE, Evans AJ, et al. Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography. J Magn Reson Imaging. 1992;2(2):135–42.
Debatin, J. F., et al. “Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography.J Magn Reson Imaging, vol. 2, no. 2, 1992, pp. 135–42. Pubmed, doi:10.1002/jmri.1880020205.
Debatin JF, Nadel SN, Paolini JF, Sostman HD, Coleman RE, Evans AJ, Beam C, Spritzer CE, Bashore TM. Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculography. J Magn Reson Imaging. 1992;2(2):135–142.
Journal cover image

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

1992

Volume

2

Issue

2

Start / End Page

135 / 142

Location

United States

Related Subject Headings

  • Ventriculography, First-Pass
  • Stroke Volume
  • Nuclear Medicine & Medical Imaging
  • Motion Pictures
  • Models, Structural
  • Magnetic Resonance Imaging
  • In Vitro Techniques
  • Humans
  • Gated Blood-Pool Imaging
  • 3202 Clinical sciences