Skip to main content
Journal cover image

125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma.

Publication ,  Journal Article
Bentel, GC; Halperin, EC; Buckley, EG
Published in: Med Dosim
1993

The application of radiation therapy in the retreatment of unilateral recurrent retinoblastoma presents a very difficult dilemma in which consideration must be given to preservation of vision in the remaining eye while tumoricidal doses of irradiation are delivered. A technique is described in which a methylmetraculate eye sphere carrying a single Iodine-125 seed was used to deliver local irradiation to the orbital tissues in a patient with multiple episodes of recurrent retinoblastoma. The tissue dose at 2 mm depth was 2630 cGy while the dose to the retina of the remaining eye and to the optic chiasm was negligible.

Duke Scholars

Published In

Med Dosim

DOI

ISSN

0958-3947

Publication Date

1993

Volume

18

Issue

1

Start / End Page

1 / 5

Location

United States

Related Subject Headings

  • Retinoblastoma
  • Radiotherapy Dosage
  • Radiography
  • Oncology & Carcinogenesis
  • Neoplasm Recurrence, Local
  • Iodine Radioisotopes
  • Humans
  • Female
  • Eye, Artificial
  • Eye Neoplasms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bentel, G. C., Halperin, E. C., & Buckley, E. G. (1993). 125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma. Med Dosim, 18(1), 1–5. https://doi.org/10.1016/0958-3947(93)90019-p
Bentel, G. C., E. C. Halperin, and E. G. Buckley. “125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma.Med Dosim 18, no. 1 (1993): 1–5. https://doi.org/10.1016/0958-3947(93)90019-p.
Bentel GC, Halperin EC, Buckley EG. 125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma. Med Dosim. 1993;18(1):1–5.
Bentel, G. C., et al. “125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma.Med Dosim, vol. 18, no. 1, 1993, pp. 1–5. Pubmed, doi:10.1016/0958-3947(93)90019-p.
Bentel GC, Halperin EC, Buckley EG. 125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma. Med Dosim. 1993;18(1):1–5.
Journal cover image

Published In

Med Dosim

DOI

ISSN

0958-3947

Publication Date

1993

Volume

18

Issue

1

Start / End Page

1 / 5

Location

United States

Related Subject Headings

  • Retinoblastoma
  • Radiotherapy Dosage
  • Radiography
  • Oncology & Carcinogenesis
  • Neoplasm Recurrence, Local
  • Iodine Radioisotopes
  • Humans
  • Female
  • Eye, Artificial
  • Eye Neoplasms