Skip to main content

Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems.

Publication ,  Journal Article
Wang, H; Jaszczak, RJ; Coleman, RE
Published in: IEEE Trans Med Imaging
1992

An object model based on combinations of object primitives is proposed for Monte Carlo simulated emission and transmission tomographic imaging systems. The primitives include ellipsoids, elliptic cylinders, tapered elliptic cylinders, rectangular solids, and their subsets: half, quarter, and eighth. The probability of a photon surviving interactions with the phantom medium is used as a weight for variance reduction. Calculation of the probability can be computationally intensive without properly organizing the inclusion of subregions within larger regions. A tree data structure is introduced to organize this inclusion relationship and used as the basis for two computationally efficient schemes for determining the intersection locations of a photon path with primitives and for identifying the attenuation coefficients for adjacent intersections for the survival probability computation. The approach has been validated by emission as well as transmission simulations. A thorax phantom containing overlapped ellipsoids and a heart composed of twelve overlapped quarter ellipsoids are employed to demonstrate the capability of the model.

Duke Scholars

Published In

IEEE Trans Med Imaging

DOI

ISSN

0278-0062

Publication Date

1992

Volume

11

Issue

3

Start / End Page

361 / 372

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 46 Information and computing sciences
  • 40 Engineering
  • 09 Engineering
  • 08 Information and Computing Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, H., Jaszczak, R. J., & Coleman, R. E. (1992). Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems. IEEE Trans Med Imaging, 11(3), 361–372. https://doi.org/10.1109/42.158940
Wang, H., R. J. Jaszczak, and R. E. Coleman. “Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems.IEEE Trans Med Imaging 11, no. 3 (1992): 361–72. https://doi.org/10.1109/42.158940.
Wang H, Jaszczak RJ, Coleman RE. Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems. IEEE Trans Med Imaging. 1992;11(3):361–72.
Wang, H., et al. “Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems.IEEE Trans Med Imaging, vol. 11, no. 3, 1992, pp. 361–72. Pubmed, doi:10.1109/42.158940.
Wang H, Jaszczak RJ, Coleman RE. Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems. IEEE Trans Med Imaging. 1992;11(3):361–372.

Published In

IEEE Trans Med Imaging

DOI

ISSN

0278-0062

Publication Date

1992

Volume

11

Issue

3

Start / End Page

361 / 372

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 46 Information and computing sciences
  • 40 Engineering
  • 09 Engineering
  • 08 Information and Computing Sciences