This study assessed physician performance in detecting the apical S3 gallop using a cardiology patient simulator. Six physicians (two cardiology fellows, two medicine residents, and two attending physicians) performed two sets of 24 cardiac examinations that included the presence or absence of an apical S3 gallop. All the examiners were able to significantly alter the prior odds of an apical S3 gallop's being present, but the cardiology fellows had higher sensitivities. Sensitivity was lower for detecting soft S3 gallops, and specificity was lower when a diastolic murmur was also present. Physician performance in detecting apical S3 gallops is variable, but can be excellent.
Duke Scholars
Published In
J Gen Intern Med
DOI
ISSN
0884-8734
Publication Date
August 1995
Volume
10
Issue
8
Start / End Page
455 / 457
Location
United States
Related Subject Headings
- Sensitivity and Specificity
- Reproducibility of Results
- Physicians
- Patient Simulation
- Likelihood Functions
- Humans
- Heart Sounds
- Heart Murmurs
- General & Internal Medicine
- 4206 Public health
Citation
APA
Chicago
ICMJE
MLA
NLM
Westman, E. C., Matchar, D. B., Samsa, G. P., Mulrow, C. D., Waugh, R. A., & Feussner, J. R. (1995). Accuracy and reliability of apical S3 gallop detection. J Gen Intern Med, 10(8), 455–457. https://doi.org/10.1007/BF02599919
Westman, E. C., D. B. Matchar, G. P. Samsa, C. D. Mulrow, R. A. Waugh, and J. R. Feussner. “Accuracy and reliability of apical S3 gallop detection.” J Gen Intern Med 10, no. 8 (August 1995): 455–57. https://doi.org/10.1007/BF02599919.
Westman EC, Matchar DB, Samsa GP, Mulrow CD, Waugh RA, Feussner JR. Accuracy and reliability of apical S3 gallop detection. J Gen Intern Med. 1995 Aug;10(8):455–7.
Westman, E. C., et al. “Accuracy and reliability of apical S3 gallop detection.” J Gen Intern Med, vol. 10, no. 8, Aug. 1995, pp. 455–57. Pubmed, doi:10.1007/BF02599919.
Westman EC, Matchar DB, Samsa GP, Mulrow CD, Waugh RA, Feussner JR. Accuracy and reliability of apical S3 gallop detection. J Gen Intern Med. 1995 Aug;10(8):455–457.
Published In
J Gen Intern Med
DOI
ISSN
0884-8734
Publication Date
August 1995
Volume
10
Issue
8
Start / End Page
455 / 457
Location
United States
Related Subject Headings
- Sensitivity and Specificity
- Reproducibility of Results
- Physicians
- Patient Simulation
- Likelihood Functions
- Humans
- Heart Sounds
- Heart Murmurs
- General & Internal Medicine
- 4206 Public health