Publication ,  Journal Article
Choi, YW; McAdams, HP; Jeon, SC; Park, CK; Lee, S-J; Kim, B-S; Kim, JH; Hahm, CK
Published in: J Comput Assist Tomogr
2002

PURPOSE: The purpose of this work was to assess the utility of low-dose spiral CT for three-dimensional imaging of the central airways. METHOD: Spiral CT was performed in 15 patients using two tube currents (50 and 240 mA), producing 30 CT data sets. Surface-rendered virtual bronchoscopy (VB) and shaded surface display (SSD) images were assessed by three radiologists for image quality. The radiologists were also asked to compare 15 matched pairs each of 50 and 240 mA VB and SSD images, blindly select the 240 mA image, and record differences in diagnostic quality between the matched images. RESULTS: No significant difference in image quality was noted with 50 or 240 mA. Only 51.1% of 240 mA SSD and 51.1% of 240 mA VB images were correctly identified. Differences in diagnostic quality, noted in 84.4% of SSD and 33% of VB image pairs, were not ascribed to image noise. CONCLUSION: Image quality of surface-rendered three-dimensional images of the central airways is preserved using a lower tube current.

Duke Scholars

Published In

J Comput Assist Tomogr

DOI

ISSN

0363-8715

Publication Date

2002

Volume

26

Issue

3

Start / End Page

335 / 341

Location

United States

Related Subject Headings

  • User-Computer Interface
  • Tomography, X-Ray Computed
  • Software
  • Radiation Dosage
  • Predictive Value of Tests
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Imaging, Three-Dimensional
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Choi, Y. W., McAdams, H. P., Jeon, S. C., Park, C. K., Lee, S.-J., Kim, B.-S., … Hahm, C. K. (2002). Low-dose spiral CT: application to surface-rendered three-dimensional imaging of central airways. J Comput Assist Tomogr, 26(3), 335–341. https://doi.org/10.1097/00004728-200205000-00003
Choi, Yo Won, H Page McAdams, Seok Chol Jeon, Choong Ki Park, Soo-Jin Lee, Bong-Soo Kim, Jong Hyo Kim, and Chang Kok Hahm. “Low-dose spiral CT: application to surface-rendered three-dimensional imaging of central airways.J Comput Assist Tomogr 26, no. 3 (2002): 335–41. https://doi.org/10.1097/00004728-200205000-00003.
Choi YW, McAdams HP, Jeon SC, Park CK, Lee S-J, Kim B-S, et al. Low-dose spiral CT: application to surface-rendered three-dimensional imaging of central airways. J Comput Assist Tomogr. 2002;26(3):335–41.
Choi, Yo Won, et al. “Low-dose spiral CT: application to surface-rendered three-dimensional imaging of central airways.J Comput Assist Tomogr, vol. 26, no. 3, 2002, pp. 335–41. Pubmed, doi:10.1097/00004728-200205000-00003.
Choi YW, McAdams HP, Jeon SC, Park CK, Lee S-J, Kim B-S, Kim JH, Hahm CK. Low-dose spiral CT: application to surface-rendered three-dimensional imaging of central airways. J Comput Assist Tomogr. 2002;26(3):335–341.

Published In

J Comput Assist Tomogr

DOI

ISSN

0363-8715

Publication Date

2002

Volume

26

Issue

3

Start / End Page

335 / 341

Location

United States

Related Subject Headings

  • User-Computer Interface
  • Tomography, X-Ray Computed
  • Software
  • Radiation Dosage
  • Predictive Value of Tests
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Imaging, Three-Dimensional