Skip to main content

Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty.

Publication ,  Journal Article
Tcheng, JE; Wells, LD; Phillips, HR; Deckelbaum, LI; Golobic, RA
Published in: Cathet Cardiovasc Diagn
January 1995

Despite expectations that excimer laser ablation would result in a low incidence of coronary dissection, studies have documented a 15-20% incidence of dissection (including a 4-6% incidence of clinically significant dissection) during excimer interventions. This investigation sought to determine if pressure pulses produced by the exposure of fluid phase media (blood and contrast) to 308-nm excimer radiation might contribute to untoward outcomes. Pressure pulses generated in these media were quantitated to be > 100 atm. In vitro ablation of porcine aorta in the presence of blood or contrast resulted in tissue dissection, while ablation in pure crystalloid did not. Next, a "flush and bathe" technique designed to replace all blood and contrast with crystalloid was applied to a pilot population of 57 consecutive patients. There were no rhythm disturbances or laser-related clinically significant dissections in this group, and the clinical success rate was 95%. In summary, this report quantitates a potential etiology for excimer dissection and suggests that replacement of blood and contrast with crystalloid might improve procedural and clinical success rates.

Duke Scholars

Published In

Cathet Cardiovasc Diagn

DOI

ISSN

0098-6569

Publication Date

January 1995

Volume

34

Issue

1

Start / End Page

15 / 22

Location

United States

Related Subject Headings

  • Swine
  • Pilot Projects
  • In Vitro Techniques
  • Humans
  • Equipment Safety
  • Coronary Vessels
  • Coronary Disease
  • Cardiovascular System & Hematology
  • Animals
  • Angioplasty, Laser
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tcheng, J. E., Wells, L. D., Phillips, H. R., Deckelbaum, L. I., & Golobic, R. A. (1995). Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty. Cathet Cardiovasc Diagn, 34(1), 15–22. https://doi.org/10.1002/ccd.1810340306
Tcheng, J. E., L. D. Wells, H. R. Phillips, L. I. Deckelbaum, and R. A. Golobic. “Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty.Cathet Cardiovasc Diagn 34, no. 1 (January 1995): 15–22. https://doi.org/10.1002/ccd.1810340306.
Tcheng JE, Wells LD, Phillips HR, Deckelbaum LI, Golobic RA. Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty. Cathet Cardiovasc Diagn. 1995 Jan;34(1):15–22.
Tcheng, J. E., et al. “Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty.Cathet Cardiovasc Diagn, vol. 34, no. 1, Jan. 1995, pp. 15–22. Pubmed, doi:10.1002/ccd.1810340306.
Tcheng JE, Wells LD, Phillips HR, Deckelbaum LI, Golobic RA. Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty. Cathet Cardiovasc Diagn. 1995 Jan;34(1):15–22.

Published In

Cathet Cardiovasc Diagn

DOI

ISSN

0098-6569

Publication Date

January 1995

Volume

34

Issue

1

Start / End Page

15 / 22

Location

United States

Related Subject Headings

  • Swine
  • Pilot Projects
  • In Vitro Techniques
  • Humans
  • Equipment Safety
  • Coronary Vessels
  • Coronary Disease
  • Cardiovascular System & Hematology
  • Animals
  • Angioplasty, Laser