Skip to main content
Journal cover image

Enhanced electrochemiluminescence sensor from tris(2,2'-bipyridyl)ruthenium(II) incorporated into MCM-41 and an ionic liquid-based carbon paste electrode.

Publication ,  Journal Article
Li, J; Huang, M; Liu, X; Wei, H; Xu, Y; Xu, G; Wang, E
Published in: The Analyst
July 2007

The electrochemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru(bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)--silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru(bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru(bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.

Published In

The Analyst

DOI

EISSN

1364-5528

ISSN

0003-2654

Publication Date

July 2007

Volume

132

Issue

7

Start / End Page

687 / 691

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0399 Other Chemical Sciences
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Li, J., Huang, M., Liu, X., Wei, H., Xu, Y., Xu, G., & Wang, E. (2007). Enhanced electrochemiluminescence sensor from tris(2,2'-bipyridyl)ruthenium(II) incorporated into MCM-41 and an ionic liquid-based carbon paste electrode. The Analyst, 132(7), 687–691. https://doi.org/10.1039/b701842h
Li, Jing, Minghua Huang, Xiaoqing Liu, Hui Wei, Yuanhong Xu, Guobao Xu, and Erkang Wang. “Enhanced electrochemiluminescence sensor from tris(2,2'-bipyridyl)ruthenium(II) incorporated into MCM-41 and an ionic liquid-based carbon paste electrode.The Analyst 132, no. 7 (July 2007): 687–91. https://doi.org/10.1039/b701842h.
Li, Jing, et al. “Enhanced electrochemiluminescence sensor from tris(2,2'-bipyridyl)ruthenium(II) incorporated into MCM-41 and an ionic liquid-based carbon paste electrode.The Analyst, vol. 132, no. 7, July 2007, pp. 687–91. Epmc, doi:10.1039/b701842h.
Journal cover image

Published In

The Analyst

DOI

EISSN

1364-5528

ISSN

0003-2654

Publication Date

July 2007

Volume

132

Issue

7

Start / End Page

687 / 691

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0399 Other Chemical Sciences
  • 0301 Analytical Chemistry