Skip to main content
Journal cover image

Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model.

Publication ,  Journal Article
Brinegar, C; Schmitter, SS; Mistry, NN; Johnson, GA; Liang, Z-P
Published in: Magn Reson Med
October 2010

Dynamic contrast-enhanced MRI (or DCE-MRI) is a useful tool for measuring blood flow and perfusion, and it has found use in the study of pulmonary perfusion in animal models. However, DCE-MRI experiments are difficult in small animals such as rats. A recently developed method known as Interleaved Radial Imaging and Sliding window-keyhole (IRIS) addresses this problem by using a data acquisition scheme that covers (k,t)-space with data acquired from multiple bolus injections of a contrast agent. However, the temporal resolution of IRIS is limited by the effects of temporal averaging inherent in the sliding window and keyhole operations. This article describes a new method to cover (k,t)-space based on the theory of partially separable functions (PSF). Specifically, a sparse sampling of (k,t)-space is performed to acquire two data sets, one with high-temporal resolution and the other with extended k-space coverage. The high-temporal resolution training data are used to determine the temporal basis functions of the PSF model, whereas the other data set is used to determine the spatial variations of the model. The proposed method was validated by simulations and demonstrated by an experimental study. In this particular study, the proposed method achieved a temporal resolution of 32 msec.

Duke Scholars

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

October 2010

Volume

64

Issue

4

Start / End Page

1162 / 1170

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Rats, Inbred F344
  • Rats
  • Pulmonary Circulation
  • Pulmonary Artery
  • Nuclear Medicine & Medical Imaging
  • Models, Cardiovascular
  • Magnetic Resonance Angiography
  • Image Interpretation, Computer-Assisted
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Brinegar, C., Schmitter, S. S., Mistry, N. N., Johnson, G. A., & Liang, Z.-P. (2010). Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model. Magn Reson Med, 64(4), 1162–1170. https://doi.org/10.1002/mrm.22500
Brinegar, Cornelius, Sarah S. Schmitter, Nilesh N. Mistry, G Allan Johnson, and Zhi-Pei Liang. “Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model.Magn Reson Med 64, no. 4 (October 2010): 1162–70. https://doi.org/10.1002/mrm.22500.
Brinegar C, Schmitter SS, Mistry NN, Johnson GA, Liang Z-P. Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model. Magn Reson Med. 2010 Oct;64(4):1162–70.
Brinegar, Cornelius, et al. “Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model.Magn Reson Med, vol. 64, no. 4, Oct. 2010, pp. 1162–70. Pubmed, doi:10.1002/mrm.22500.
Brinegar C, Schmitter SS, Mistry NN, Johnson GA, Liang Z-P. Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model. Magn Reson Med. 2010 Oct;64(4):1162–1170.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

October 2010

Volume

64

Issue

4

Start / End Page

1162 / 1170

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Rats, Inbred F344
  • Rats
  • Pulmonary Circulation
  • Pulmonary Artery
  • Nuclear Medicine & Medical Imaging
  • Models, Cardiovascular
  • Magnetic Resonance Angiography
  • Image Interpretation, Computer-Assisted