Skip to main content
Journal cover image

A dose calculation method including scatter for IMRT optimization.

Publication ,  Journal Article
Wu, Q
Published in: Phys Med Biol
October 7, 2004

IMRT optimization is an iterative process in which many dose calculations may be necessary. A fast and accurate dose calculation engine is essential for the optimization program to converge to a reliable solution in a reasonable time. Previously we developed a fast dose calculation method for IMRT optimization based on the table lookup (TLP). The TLP kernel is constructed from the dose distributions computed from an accurate superposition/convolution (SC) algorithm at the beginning. Dose calculations at subsequent iterations are performed by looking up the kernel in memory, therefore are very fast. However, it is assumed by the TLP that the beamlet only deposits doses to the voxels on its path. In this paper, we propose an improved table lookup based dose calculation method that includes the scatter contribution (TLPS). The intensity map for each beam is decomposed into an even and an odd checkbox-type pattern for the construction of the kernel for primary and scatter components. The performance of this algorithm is compared with the methods of SC only and TLP without scatter on a few clinical cases and the advantages of speed and accuracy are demonstrated. This method is especially useful for those optimizations that utilize the IMRT optimization as an inner loop, such as the beam angle optimization.

Duke Scholars

Published In

Phys Med Biol

DOI

ISSN

0031-9155

Publication Date

October 7, 2004

Volume

49

Issue

19

Start / End Page

4611 / 4621

Location

England

Related Subject Headings

  • Scattering, Radiation
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiometry
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Head and Neck Neoplasms
  • Algorithms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wu, Q. (2004). A dose calculation method including scatter for IMRT optimization. Phys Med Biol, 49(19), 4611–4621. https://doi.org/10.1088/0031-9155/49/19/011
Wu, Qiuwen. “A dose calculation method including scatter for IMRT optimization.Phys Med Biol 49, no. 19 (October 7, 2004): 4611–21. https://doi.org/10.1088/0031-9155/49/19/011.
Wu Q. A dose calculation method including scatter for IMRT optimization. Phys Med Biol. 2004 Oct 7;49(19):4611–21.
Wu, Qiuwen. “A dose calculation method including scatter for IMRT optimization.Phys Med Biol, vol. 49, no. 19, Oct. 2004, pp. 4611–21. Pubmed, doi:10.1088/0031-9155/49/19/011.
Wu Q. A dose calculation method including scatter for IMRT optimization. Phys Med Biol. 2004 Oct 7;49(19):4611–4621.
Journal cover image

Published In

Phys Med Biol

DOI

ISSN

0031-9155

Publication Date

October 7, 2004

Volume

49

Issue

19

Start / End Page

4611 / 4621

Location

England

Related Subject Headings

  • Scattering, Radiation
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiometry
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Head and Neck Neoplasms
  • Algorithms