Skip to main content

Tear flow analysis through the upper and lower systems.

Publication ,  Journal Article
Daubert, J; Nik, N; Chandeyssoun, PA; el-Choufi, L
Published in: Ophthalmic Plast Reconstr Surg
1990

Using quantitative lacrimal scintillography, tear flow in the normal state was analyzed in 11 asymptomatic volunteers. The results were compared to states with the superior punctum occluded, and to those with the inferior punctum occluded. No significant difference in tear flow between the superior and inferior canaliculi was appreciated (P less than 0.05). Furthermore, no significant difference was noted in overall basal tear flow when one canaliculus was blocked compared to the patent system (P less than 0.05). This implies increased tear flow through the patent canaliculus when the opposite one is blocked. The clinical implications of these results are important in canaliculus repair after injury.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ophthalmic Plast Reconstr Surg

DOI

ISSN

0740-9303

Publication Date

1990

Volume

6

Issue

3

Start / End Page

193 / 196

Location

United States

Related Subject Headings

  • Tears
  • Radionuclide Imaging
  • Prospective Studies
  • Ophthalmology & Optometry
  • Male
  • Lacrimal Duct Obstruction
  • Lacrimal Apparatus
  • Humans
  • Female
  • Adult
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Daubert, J., Nik, N., Chandeyssoun, P. A., & el-Choufi, L. (1990). Tear flow analysis through the upper and lower systems. Ophthalmic Plast Reconstr Surg, 6(3), 193–196. https://doi.org/10.1097/00002341-199009000-00008
Daubert, J., N. Nik, P. A. Chandeyssoun, and L. el-Choufi. “Tear flow analysis through the upper and lower systems.Ophthalmic Plast Reconstr Surg 6, no. 3 (1990): 193–96. https://doi.org/10.1097/00002341-199009000-00008.
Daubert J, Nik N, Chandeyssoun PA, el-Choufi L. Tear flow analysis through the upper and lower systems. Ophthalmic Plast Reconstr Surg. 1990;6(3):193–6.
Daubert, J., et al. “Tear flow analysis through the upper and lower systems.Ophthalmic Plast Reconstr Surg, vol. 6, no. 3, 1990, pp. 193–96. Pubmed, doi:10.1097/00002341-199009000-00008.
Daubert J, Nik N, Chandeyssoun PA, el-Choufi L. Tear flow analysis through the upper and lower systems. Ophthalmic Plast Reconstr Surg. 1990;6(3):193–196.

Published In

Ophthalmic Plast Reconstr Surg

DOI

ISSN

0740-9303

Publication Date

1990

Volume

6

Issue

3

Start / End Page

193 / 196

Location

United States

Related Subject Headings

  • Tears
  • Radionuclide Imaging
  • Prospective Studies
  • Ophthalmology & Optometry
  • Male
  • Lacrimal Duct Obstruction
  • Lacrimal Apparatus
  • Humans
  • Female
  • Adult