Skip to main content

Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).

Publication ,  Journal Article
Zareba, W; Klein, H; Cygankiewicz, I; Hall, WJ; McNitt, S; Brown, M; Cannom, D; Daubert, JP; Eldar, M; Gold, MR; Goldberger, JJ; Goldenberg, I ...
Published in: Circulation
March 15, 2011

BACKGROUND: This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial. METHODS AND RESULTS: Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly (P < 0.001) lower in LBBB patients (0.47; P < 0.001) than in non-LBBB patients (1.24; P = 0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly (P < 0.001) greater reduction in left ventricular volumes and increase in ejection fraction with CRT-D in LBBB than in non-LBBB patients. CONCLUSIONS: Heart failure patients with New York Heart Association class I or II and ejection fraction ≤ 30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances). CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

March 15, 2011

Volume

123

Issue

10

Start / End Page

1061 / 1072

Location

United States

Related Subject Headings

  • Ventricular Fibrillation
  • Ultrasonography
  • Treatment Outcome
  • Tachycardia, Ventricular
  • Stroke Volume
  • Risk
  • Middle Aged
  • Male
  • Humans
  • Heart Failure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zareba, W., Klein, H., Cygankiewicz, I., Hall, W. J., McNitt, S., Brown, M., … MADIT-CRT Investigators, . (2011). Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT). Circulation, 123(10), 1061–1072. https://doi.org/10.1161/CIRCULATIONAHA.110.960898
Zareba, Wojciech, Helmut Klein, Iwona Cygankiewicz, W Jackson Hall, Scott McNitt, Mary Brown, David Cannom, et al. “Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).Circulation 123, no. 10 (March 15, 2011): 1061–72. https://doi.org/10.1161/CIRCULATIONAHA.110.960898.
Zareba, Wojciech, et al. “Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).Circulation, vol. 123, no. 10, Mar. 2011, pp. 1061–72. Pubmed, doi:10.1161/CIRCULATIONAHA.110.960898.
Zareba W, Klein H, Cygankiewicz I, Hall WJ, McNitt S, Brown M, Cannom D, Daubert JP, Eldar M, Gold MR, Goldberger JJ, Goldenberg I, Lichstein E, Pitschner H, Rashtian M, Solomon S, Viskin S, Wang P, Moss AJ, MADIT-CRT Investigators. Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT). Circulation. 2011 Mar 15;123(10):1061–1072.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

March 15, 2011

Volume

123

Issue

10

Start / End Page

1061 / 1072

Location

United States

Related Subject Headings

  • Ventricular Fibrillation
  • Ultrasonography
  • Treatment Outcome
  • Tachycardia, Ventricular
  • Stroke Volume
  • Risk
  • Middle Aged
  • Male
  • Humans
  • Heart Failure