Skip to main content
Journal cover image

Comparative effectiveness of low- and high-fidelity bronchoscopy simulation for training in conventional transbronchial needle aspiration and user preferences.

Publication ,  Journal Article
Davoudi, M; Wahidi, MM; Zamanian Rohani, N; Colt, HG
Published in: Respiration
2010

BACKGROUND: Conventional transbronchial needle aspiration (TBNA) can be learned using high-fidelity virtual-reality platforms and low-fidelity models comprised of molded silicone or excised animal airways. OBJECTIVES: The purpose of this study was to determine perceptions and preferences of learners and instructors regarding the comparative effectiveness of low-fidelity and high-fidelity bronchoscopy simulation for training in TBNA. METHODS: During the 2008 annual CHEST conference, a prospective randomized crossover design was used to train study participants in three methods of conventional TBNA using low- and high-fidelity models. Likert style questions were administered to learners and instructors in order to elicit preferences and opinions regarding educational effectiveness of the models. Results were tabulated and depicted in graphic format, with medians calculated. RESULTS: Learners felt that the models were equally enjoyable (13-13) and enthusiasm generating (low 17-high 15). There was preference for low-fidelity in terms of realism (23-17), ease of learning (20-6), and learning all three TBNA methods (31-7 for hub-against-wall, 31-6 for jabbing, 29-6 for piggyback). Low-fidelity was preferred as an ideal model overall (19-11). Instructors thought that low-fidelity was more useful in teaching TBNA (9-0 for all three methods). Instructors perceived the low-fidelity model overall as an ideal tool for learning TBNA (8-0) and a more effective teaching instrument (8-0). CONCLUSION: Based on learner and instructor perceptions, a low-fidelity model is superior to a high-fidelity platform for training in three methods of conventional TBNA.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Respiration

DOI

EISSN

1423-0356

Publication Date

2010

Volume

80

Issue

4

Start / End Page

327 / 334

Location

Switzerland

Related Subject Headings

  • Respiratory System
  • Random Allocation
  • Models, Biological
  • Models, Anatomic
  • Middle Aged
  • Male
  • Lung
  • Humans
  • Female
  • Cross-Over Studies
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Davoudi, M., Wahidi, M. M., Zamanian Rohani, N., & Colt, H. G. (2010). Comparative effectiveness of low- and high-fidelity bronchoscopy simulation for training in conventional transbronchial needle aspiration and user preferences. Respiration, 80(4), 327–334. https://doi.org/10.1159/000318674
Davoudi, Mohsen, Momen M. Wahidi, Nazanin Zamanian Rohani, and Henri G. Colt. “Comparative effectiveness of low- and high-fidelity bronchoscopy simulation for training in conventional transbronchial needle aspiration and user preferences.Respiration 80, no. 4 (2010): 327–34. https://doi.org/10.1159/000318674.
Davoudi, Mohsen, et al. “Comparative effectiveness of low- and high-fidelity bronchoscopy simulation for training in conventional transbronchial needle aspiration and user preferences.Respiration, vol. 80, no. 4, 2010, pp. 327–34. Pubmed, doi:10.1159/000318674.
Journal cover image

Published In

Respiration

DOI

EISSN

1423-0356

Publication Date

2010

Volume

80

Issue

4

Start / End Page

327 / 334

Location

Switzerland

Related Subject Headings

  • Respiratory System
  • Random Allocation
  • Models, Biological
  • Models, Anatomic
  • Middle Aged
  • Male
  • Lung
  • Humans
  • Female
  • Cross-Over Studies